首页 > 最新文献

2012 IEEE/MTT-S International Microwave Symposium Digest最新文献

英文 中文
Noise figure characterization of a subharmonic graphene FET mixer 次谐波石墨烯FET混频器的噪声系数表征
Pub Date : 2012-06-17 DOI: 10.1109/MWSYM.2012.6259519
M. Andersson, O. Habibpour, J. Vukusic, J. Stake
We report on the first room temperature noise figure measurement of a graphene FET subharmonic resistive mixer in the interval fRF = 2-5 GHz. Due to an 8 nm thin Al2O3 gate dielectric it can operate with a conversion loss in the range 20–22 dB at only 0 dBm of local oscillator power. The measurement yields a noise figure close to the conversion loss, thus determining the noise to be thermal in origin, which is promising for cryogenic applications. The general route to lower noise figure is an improvement of the conversion loss.
本文报道了石墨烯FET亚谐波阻性混频器在fRF = 2-5 GHz范围内的首次室温噪声系数测量。由于采用8nm薄Al2O3栅极电介质,在本地振荡器功率仅为0 dBm的情况下,转换损耗在20-22 dB范围内。测量产生的噪声值接近转换损耗,从而确定噪声是热源的,这对于低温应用是有希望的。降低噪声系数的一般途径是提高转换损耗。
{"title":"Noise figure characterization of a subharmonic graphene FET mixer","authors":"M. Andersson, O. Habibpour, J. Vukusic, J. Stake","doi":"10.1109/MWSYM.2012.6259519","DOIUrl":"https://doi.org/10.1109/MWSYM.2012.6259519","url":null,"abstract":"We report on the first room temperature noise figure measurement of a graphene FET subharmonic resistive mixer in the interval fRF = 2-5 GHz. Due to an 8 nm thin Al2O3 gate dielectric it can operate with a conversion loss in the range 20–22 dB at only 0 dBm of local oscillator power. The measurement yields a noise figure close to the conversion loss, thus determining the noise to be thermal in origin, which is promising for cryogenic applications. The general route to lower noise figure is an improvement of the conversion loss.","PeriodicalId":6385,"journal":{"name":"2012 IEEE/MTT-S International Microwave Symposium Digest","volume":"117 1","pages":"1-3"},"PeriodicalIF":0.0,"publicationDate":"2012-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82570942","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
A D-band compact rat-race coupler using novel phase inverter in standard CMOS process 一种采用标准CMOS工艺的新型相位逆变器的d波段紧凑型大鼠赛跑耦合器
Pub Date : 2012-06-17 DOI: 10.1109/MWSYM.2012.6259758
Debin Hou, W. Hong, W. Goh, A. Arasu, Y. Xiong, Chang Liu, M. Madihian
This paper describes a D-band on-chip rat-race coupler using a novel phase inverter and developed in a standard CMOS process. The simple structural phase inverter which is based on the characteristic impedance and phase difference analysis has demonstrated its potential for wideband and compact millimeter-wave frequency range applications. The developed rat-race coupler using the proposed phase inverter, features a 40% size reduction and over 60% bandwidth improvement compared to conventional structures. In the complete D-band range, measured amplitude and phase imbalances for the coupler are within 0.5 dB and 15°, respectively. The port-to-port isolation is better than 25 dB in the D-band range with the highest value of 41 dB at 118 GHz. The insertion loss achieves 1.2 ± 0.3 dB and the coral size of the coupler is only 290 × 162 µm2. The proposed coupler has a huge potential for integration in single-chip systems over 100 GHz.
本文介绍了一种采用新型相位逆变器的d波段片上大鼠竞赛耦合器,并采用标准的CMOS工艺进行了研制。基于特性阻抗和相位差分析的结构简单的逆变器在宽频带和紧凑的毫米波频率范围内的应用已经显示出它的潜力。与传统结构相比,使用所提出的相位逆变器开发的老鼠竞赛耦合器的尺寸减小了40%,带宽提高了60%以上。在整个d波段范围内,耦合器的测量幅度和相位不平衡分别在0.5 dB和15°以内。端口到端口的隔离度在d频段范围内优于25 dB,在118 GHz时最高为41 dB。插入损耗达到1.2±0.3 dB,耦合器的珊瑚尺寸仅为290 × 162µm2。提出的耦合器在100 GHz以上的单芯片系统中具有巨大的集成潜力。
{"title":"A D-band compact rat-race coupler using novel phase inverter in standard CMOS process","authors":"Debin Hou, W. Hong, W. Goh, A. Arasu, Y. Xiong, Chang Liu, M. Madihian","doi":"10.1109/MWSYM.2012.6259758","DOIUrl":"https://doi.org/10.1109/MWSYM.2012.6259758","url":null,"abstract":"This paper describes a D-band on-chip rat-race coupler using a novel phase inverter and developed in a standard CMOS process. The simple structural phase inverter which is based on the characteristic impedance and phase difference analysis has demonstrated its potential for wideband and compact millimeter-wave frequency range applications. The developed rat-race coupler using the proposed phase inverter, features a 40% size reduction and over 60% bandwidth improvement compared to conventional structures. In the complete D-band range, measured amplitude and phase imbalances for the coupler are within 0.5 dB and 15°, respectively. The port-to-port isolation is better than 25 dB in the D-band range with the highest value of 41 dB at 118 GHz. The insertion loss achieves 1.2 ± 0.3 dB and the coral size of the coupler is only 290 × 162 µm2. The proposed coupler has a huge potential for integration in single-chip systems over 100 GHz.","PeriodicalId":6385,"journal":{"name":"2012 IEEE/MTT-S International Microwave Symposium Digest","volume":"64 1","pages":"1-3"},"PeriodicalIF":0.0,"publicationDate":"2012-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"78669199","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Dynamic linearization of diodes for high speed and peak power detection applications 用于高速和峰值功率检测应用的二极管动态线性化
Pub Date : 2012-06-17 DOI: 10.1109/MWSYM.2012.6259710
Abul Hasan, M. Helaoui, F. Ghannouchi
In this paper we show that the characteristics of diode based peak power detectors are dependent on the type of input excitation signal. Linearization of peak power detectors using continuous wave (CW) characterized data results in inaccurate linearized peak powers when compared with peak power data obtained from actual measurements. By comparing the diode power detector behavior under different types of excitations, it is proved that CW characterized data can't be used to linearize peak power detectors when excited with real (modulated) signals having high peak-to-average-power (PAPR) value. For accurate linearization, two new approaches have been proposed; one using calibration factor and another using dynamic calibration. The proposed approaches improved the accuracy of the diode peak power detector used for measurement validation.
本文研究了基于二极管的峰值功率检测器的特性与输入激励信号的类型有关。使用连续波(CW)特征数据的峰值功率检测器的线性化结果与从实际测量中获得的峰值功率数据相比,线性化的峰值功率不准确。通过比较不同激励方式下二极管功率检测器的性能,证明了当用具有较高峰均功率(PAPR)值的真实(调制)信号激励时,连续波特征数据不能用于峰值功率检测器的线性化。为了实现精确的线性化,提出了两种新的方法;一个使用校准因子,另一个使用动态校准。提出的方法提高了用于测量验证的二极管峰值功率检测器的精度。
{"title":"Dynamic linearization of diodes for high speed and peak power detection applications","authors":"Abul Hasan, M. Helaoui, F. Ghannouchi","doi":"10.1109/MWSYM.2012.6259710","DOIUrl":"https://doi.org/10.1109/MWSYM.2012.6259710","url":null,"abstract":"In this paper we show that the characteristics of diode based peak power detectors are dependent on the type of input excitation signal. Linearization of peak power detectors using continuous wave (CW) characterized data results in inaccurate linearized peak powers when compared with peak power data obtained from actual measurements. By comparing the diode power detector behavior under different types of excitations, it is proved that CW characterized data can't be used to linearize peak power detectors when excited with real (modulated) signals having high peak-to-average-power (PAPR) value. For accurate linearization, two new approaches have been proposed; one using calibration factor and another using dynamic calibration. The proposed approaches improved the accuracy of the diode peak power detector used for measurement validation.","PeriodicalId":6385,"journal":{"name":"2012 IEEE/MTT-S International Microwave Symposium Digest","volume":"37 1","pages":"1-3"},"PeriodicalIF":0.0,"publicationDate":"2012-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"87670932","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
A parallel-trace high-Q planar spiral coil for biomedical implants 一种用于生物医学植入物的平行走线高q平面螺旋线圈
Pub Date : 2012-06-17 DOI: 10.1109/MWSYM.2012.6259488
Hao Jiang, S. Zhou, Di Lan, Junmin Zhang, H. Shahnasser, K. Goldman, S. Roy
High-Q inductive coils are essential components in biomedical implants for efficient wireless charging and effective wireless sensing. The planar spiral coil (PSC) that can be easily optimized and reliably fabricated by lithographic tools is a preferred candidate. To support the inductive coupling at MHz range, the size of PSCs used in implants is much larger than those used in wireless communication circuits. Therefore, to achieve high Q, it is imperative to reduce the metal trace's unit-length-resistance. In this paper, multiple parallel-connected metal traces, instead of a conventional single trace, have been employed to reduce the unit-length-resistance by mitigating the skin effect. Although the approach was used to make stranded wires for mega-watts transmission systems, it has been used to design PSCs for the first time. The parallel-trace PSC exhibits 38%~53% improvements in Q when it resonates with a capacitor at ~10 MHz. Measurement results also indicate that there is ~10% inductance reduction in the parallel-trace PSC compared to the single-trace PSC of the same design. Measurement results also indicate that, in a parallel-trace PSC, the length difference between the parallel-connected, side-by-side traces when they are winded into a coil, and the dielectric environment difference when they are placed in different layers, can be neglected when the operating frequency is less than the PSCs self-resonating frequency. Utilizing widely-available planar fabrication technologies, the parallel-trace PSC can be widely adopted in biomedical implants.
高q电感线圈是生物医学植入物中实现高效无线充电和有效无线传感的重要部件。平面螺旋线圈(PSC)易于优化和可靠的光刻工具是首选的候选人。为了支持MHz范围内的电感耦合,植入物中使用的psc尺寸要比无线通信电路中使用的psc尺寸大得多。因此,要实现高Q,必须降低金属迹线的单位长度电阻。在本文中,多个并联的金属走线,而不是传统的单一走线,已被用来减少单位长度电阻,通过减轻趋肤效应。虽然这种方法被用于制造兆瓦级传输系统的绞合线,但它第一次被用于设计psc。当并联走线PSC与~10 MHz的电容谐振时,其Q值提高了38%~53%。测量结果还表明,与相同设计的单走线PSC相比,并联走线PSC的电感减小了约10%。测量结果还表明,在并联走线PSC中,当工作频率小于PSC自谐振频率时,平行连接的并排走线缠绕成线圈时的长度差和放置在不同层时的介电环境差可以忽略不计。利用广泛可用的平面制造技术,平行走线PSC可以广泛应用于生物医学植入物。
{"title":"A parallel-trace high-Q planar spiral coil for biomedical implants","authors":"Hao Jiang, S. Zhou, Di Lan, Junmin Zhang, H. Shahnasser, K. Goldman, S. Roy","doi":"10.1109/MWSYM.2012.6259488","DOIUrl":"https://doi.org/10.1109/MWSYM.2012.6259488","url":null,"abstract":"High-Q inductive coils are essential components in biomedical implants for efficient wireless charging and effective wireless sensing. The planar spiral coil (PSC) that can be easily optimized and reliably fabricated by lithographic tools is a preferred candidate. To support the inductive coupling at MHz range, the size of PSCs used in implants is much larger than those used in wireless communication circuits. Therefore, to achieve high Q, it is imperative to reduce the metal trace's unit-length-resistance. In this paper, multiple parallel-connected metal traces, instead of a conventional single trace, have been employed to reduce the unit-length-resistance by mitigating the skin effect. Although the approach was used to make stranded wires for mega-watts transmission systems, it has been used to design PSCs for the first time. The parallel-trace PSC exhibits 38%~53% improvements in Q when it resonates with a capacitor at ~10 MHz. Measurement results also indicate that there is ~10% inductance reduction in the parallel-trace PSC compared to the single-trace PSC of the same design. Measurement results also indicate that, in a parallel-trace PSC, the length difference between the parallel-connected, side-by-side traces when they are winded into a coil, and the dielectric environment difference when they are placed in different layers, can be neglected when the operating frequency is less than the PSCs self-resonating frequency. Utilizing widely-available planar fabrication technologies, the parallel-trace PSC can be widely adopted in biomedical implants.","PeriodicalId":6385,"journal":{"name":"2012 IEEE/MTT-S International Microwave Symposium Digest","volume":"106 1","pages":"1-3"},"PeriodicalIF":0.0,"publicationDate":"2012-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"87818494","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Robustness of RF MEMS capacitive switches in Harsh Environments 射频MEMS电容开关在恶劣环境下的鲁棒性
Pub Date : 2012-06-17 DOI: 10.1109/MWSYM.2012.6259627
C. Goldsmith, J.C.M. Hwang, C. Gudeman, O. Auciello, J. Ebel, H. Newman
RF MEMS switches have evolved significantly since the early days of testing unpackaged devices in an uncontrolled environment with failure modes that could only be guessed at. Today, MEMS switch technology has effective, RF-friendly wafer-level packaging, demonstrated temperature robustness, and failure modes that can be characterized and modeled from accelerated testing. This presentation overviews the advances in packaging, reliability, and environmental robustness for RF MEMS switches made on DARPA's HERMIT program. It also includes more recent developments in novel nanostructured switch dielectrics, CMOS co-integration, intelligent CMOS control, and operation of RF MEMS in adverse thermal and radiation environments.
自早期在不受控制的环境中测试未封装器件以来,RF MEMS开关已经发生了重大变化,其故障模式只能猜测。今天,MEMS开关技术具有有效的,rf友好的晶圆级封装,具有温度稳健性,并且可以通过加速测试来表征和建模故障模式。本报告概述了DARPA的HERMIT项目中射频MEMS开关在封装、可靠性和环境稳健性方面的进展。它还包括新型纳米结构开关电介质,CMOS协整,智能CMOS控制以及RF MEMS在不利热和辐射环境中的操作的最新发展。
{"title":"Robustness of RF MEMS capacitive switches in Harsh Environments","authors":"C. Goldsmith, J.C.M. Hwang, C. Gudeman, O. Auciello, J. Ebel, H. Newman","doi":"10.1109/MWSYM.2012.6259627","DOIUrl":"https://doi.org/10.1109/MWSYM.2012.6259627","url":null,"abstract":"RF MEMS switches have evolved significantly since the early days of testing unpackaged devices in an uncontrolled environment with failure modes that could only be guessed at. Today, MEMS switch technology has effective, RF-friendly wafer-level packaging, demonstrated temperature robustness, and failure modes that can be characterized and modeled from accelerated testing. This presentation overviews the advances in packaging, reliability, and environmental robustness for RF MEMS switches made on DARPA's HERMIT program. It also includes more recent developments in novel nanostructured switch dielectrics, CMOS co-integration, intelligent CMOS control, and operation of RF MEMS in adverse thermal and radiation environments.","PeriodicalId":6385,"journal":{"name":"2012 IEEE/MTT-S International Microwave Symposium Digest","volume":"8 1","pages":"1-3"},"PeriodicalIF":0.0,"publicationDate":"2012-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"87851899","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
A 58.4mW solid-state power amplifier at 220 GHz using InP HBTs 采用InP hbt的220 GHz 58.4mW固态功率放大器
Pub Date : 2012-06-17 DOI: 10.1109/MWSYM.2012.6259659
T. Reed, M. Rodwell, Z. Griffith, P. Rowell, M. Field, M. Urteaga
A 220 GHz solid state power amplifier MMIC is presented demonstrating 58.4 mW of output power with 5.4dB compressed gain. The 8-cell amplifier has a small signal gain of 8.9 dB at 220 GHz, and 3-dB bandwidth from 206 to 242GHz. Amplifier cells are formed using a 250nm InP HBT technology and a 5um BCB thin-film, non-inverted microstrip wiring environment. Power division and combining of the eight amplifier cells is done by a 2-1 quarter wave combiner series connected to a 4-1 Dolph-Chebyshev combiner. More than 50mW of output power was observed from 215 to 225GHz.
提出了一种220 GHz固态功率放大器MMIC,其输出功率为58.4 mW,压缩增益为5.4dB。8单元放大器在220 GHz时具有8.9 dB的小信号增益,在206至242GHz范围内具有3 dB的带宽。放大器单元采用250nm InP HBT技术和5um BCB薄膜,非倒置微带布线环境形成。8个放大器单元的功率划分和组合由连接到4-1 dolphi - chebyshev合成器的2-1四分之一波合成器系列完成。在215至225GHz范围内观察到超过50mW的输出功率。
{"title":"A 58.4mW solid-state power amplifier at 220 GHz using InP HBTs","authors":"T. Reed, M. Rodwell, Z. Griffith, P. Rowell, M. Field, M. Urteaga","doi":"10.1109/MWSYM.2012.6259659","DOIUrl":"https://doi.org/10.1109/MWSYM.2012.6259659","url":null,"abstract":"A 220 GHz solid state power amplifier MMIC is presented demonstrating 58.4 mW of output power with 5.4dB compressed gain. The 8-cell amplifier has a small signal gain of 8.9 dB at 220 GHz, and 3-dB bandwidth from 206 to 242GHz. Amplifier cells are formed using a 250nm InP HBT technology and a 5um BCB thin-film, non-inverted microstrip wiring environment. Power division and combining of the eight amplifier cells is done by a 2-1 quarter wave combiner series connected to a 4-1 Dolph-Chebyshev combiner. More than 50mW of output power was observed from 215 to 225GHz.","PeriodicalId":6385,"journal":{"name":"2012 IEEE/MTT-S International Microwave Symposium Digest","volume":"31 1","pages":"1-3"},"PeriodicalIF":0.0,"publicationDate":"2012-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86839792","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 14
Millimeter-wave broadband positioning system for indoor applications 用于室内应用的毫米波宽带定位系统
Pub Date : 2012-06-17 DOI: 10.1109/MWSYM.2012.6258333
M. Bocquet, C. Loyez, M. Fryziel, N. Rolland
This paper presents the performance of a millimeter wave (MMW) positioning system operating in indoor environment and using broadband impulse signals. The main original contribution is an approach based on a focusing technique to minimize the performance degradations due to the multipath propagation. Experimental results validate the ability of the topology to perform multi-laterations based on a specific cooperation between sensors. The used focusing technique is detailed and its impact on the positioning accuracy is validated by numerous measurements.
介绍了一种利用宽带脉冲信号在室内环境下工作的毫米波定位系统的性能。主要的原始贡献是一种基于聚焦技术的方法,以最小化由于多径传播引起的性能下降。实验结果验证了基于传感器之间特定合作的拓扑结构执行多方位的能力。详细介绍了所采用的聚焦技术,并通过大量测量验证了其对定位精度的影响。
{"title":"Millimeter-wave broadband positioning system for indoor applications","authors":"M. Bocquet, C. Loyez, M. Fryziel, N. Rolland","doi":"10.1109/MWSYM.2012.6258333","DOIUrl":"https://doi.org/10.1109/MWSYM.2012.6258333","url":null,"abstract":"This paper presents the performance of a millimeter wave (MMW) positioning system operating in indoor environment and using broadband impulse signals. The main original contribution is an approach based on a focusing technique to minimize the performance degradations due to the multipath propagation. Experimental results validate the ability of the topology to perform multi-laterations based on a specific cooperation between sensors. The used focusing technique is detailed and its impact on the positioning accuracy is validated by numerous measurements.","PeriodicalId":6385,"journal":{"name":"2012 IEEE/MTT-S International Microwave Symposium Digest","volume":"15 1","pages":"1-3"},"PeriodicalIF":0.0,"publicationDate":"2012-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86946042","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
A new approach on broadband calibration methods for free space applications 自由空间应用宽带标定方法的新途径
Pub Date : 2012-06-17 DOI: 10.1109/MWSYM.2012.6259615
B. Will, I. Rolfes
The application of free space measurements depends on the practicability of the respective calibration procedure. Due to necessary changes of the distance between used antennas or a precise positioning of calibration standards, the suitability of free space setups is limited. This contribution deals with a calibration technique for free space applications, which uses the change of the electrical length by means of small frequency variations. Thus, this technique enables free space calibrations without the necessity of antenna displacements. Furthermore, the bandwidth of this procedure is not limited due to ambiguities of mechanical displacements during the calibration procedure. Additionally, the presented calibration technique is based on the Thru-Line-Network (TLN) method. Hence, symmetrical and reciprocal measurement objects can be characterized within the calibration procedure.
自由空间测量的应用取决于各自校准程序的实用性。由于所使用天线之间的距离需要改变或校准标准的精确定位,自由空间设置的适用性受到限制。这一贡献涉及自由空间应用的校准技术,该技术通过小频率变化来改变电长度。因此,该技术可以实现自由空间校准,而无需天线位移。此外,该程序的带宽不受校准过程中机械位移的模糊性的限制。此外,本文提出的标定技术是基于透线网络(TLN)方法。因此,对称和互反的测量对象可以在校准过程中表征。
{"title":"A new approach on broadband calibration methods for free space applications","authors":"B. Will, I. Rolfes","doi":"10.1109/MWSYM.2012.6259615","DOIUrl":"https://doi.org/10.1109/MWSYM.2012.6259615","url":null,"abstract":"The application of free space measurements depends on the practicability of the respective calibration procedure. Due to necessary changes of the distance between used antennas or a precise positioning of calibration standards, the suitability of free space setups is limited. This contribution deals with a calibration technique for free space applications, which uses the change of the electrical length by means of small frequency variations. Thus, this technique enables free space calibrations without the necessity of antenna displacements. Furthermore, the bandwidth of this procedure is not limited due to ambiguities of mechanical displacements during the calibration procedure. Additionally, the presented calibration technique is based on the Thru-Line-Network (TLN) method. Hence, symmetrical and reciprocal measurement objects can be characterized within the calibration procedure.","PeriodicalId":6385,"journal":{"name":"2012 IEEE/MTT-S International Microwave Symposium Digest","volume":"11 1","pages":"1-3"},"PeriodicalIF":0.0,"publicationDate":"2012-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"87128590","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
A dual-band oscillator with reconfigurable cavity-backed complementary split-ring resonator 具有可重构腔背互补劈环谐振器的双频振荡器
Pub Date : 2012-06-17 DOI: 10.1109/MWSYM.2012.6259451
Yuandan Dong, T. Itoh
A novel C-band low phase noise dual-band oscillator using a reconfigurable cavity-backed complementary split-ring resonator (CSRR) is proposed and developed based on the substrate integrated waveguide (SIW) technology. The resonator consists of a PIN diode switch and a CSRR resonator embedded in an SIW cavity. It is able to provide two different resonance frequencies by selecting different diode modes. A switchable matching stub is used for matching each of the two states. Measured results show that the proposed oscillator is able to operate at 2.675 and 3.77 GHz, respectively, with a phase noise of 105.5 and 99.6 dBc/Hz at a 100 KHz offset.
基于衬底集成波导(SIW)技术,提出并研制了一种基于可重构腔背互补劈环谐振器(CSRR)的新型c波段低相位噪声双频振荡器。谐振器由一个PIN二极管开关和一个嵌入在SIW腔中的CSRR谐振器组成。它可以通过选择不同的二极管模式来提供两种不同的谐振频率。一个可切换的匹配存根用于匹配这两种状态。测量结果表明,该振荡器工作频率分别为2.675 GHz和3.77 GHz,相位噪声分别为105.5和99.6 dBc/Hz。
{"title":"A dual-band oscillator with reconfigurable cavity-backed complementary split-ring resonator","authors":"Yuandan Dong, T. Itoh","doi":"10.1109/MWSYM.2012.6259451","DOIUrl":"https://doi.org/10.1109/MWSYM.2012.6259451","url":null,"abstract":"A novel C-band low phase noise dual-band oscillator using a reconfigurable cavity-backed complementary split-ring resonator (CSRR) is proposed and developed based on the substrate integrated waveguide (SIW) technology. The resonator consists of a PIN diode switch and a CSRR resonator embedded in an SIW cavity. It is able to provide two different resonance frequencies by selecting different diode modes. A switchable matching stub is used for matching each of the two states. Measured results show that the proposed oscillator is able to operate at 2.675 and 3.77 GHz, respectively, with a phase noise of 105.5 and 99.6 dBc/Hz at a 100 KHz offset.","PeriodicalId":6385,"journal":{"name":"2012 IEEE/MTT-S International Microwave Symposium Digest","volume":"11 1","pages":"1-3"},"PeriodicalIF":0.0,"publicationDate":"2012-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86478015","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 18
A compact-size packaged third-order harmonic tag for intraocular pressure (IOP) monitoring inside a mouse eye 一种紧凑尺寸的三阶谐波标签,用于监测小鼠眼内的眼压
Pub Date : 2012-06-17 DOI: 10.1109/MWSYM.2012.6259672
Dohyuk Ha, Tse-Yu Lin, W. D. de Vries, Byungguk Kim, A. Chlebowski, S. John, P. Irazoqui, W. Chappell
This paper shows measurement of intraocular pressure (IOP) within a mouse eye. Three main challenges faced the development of a device for the measurement: the size of the mouse eye, the depth of the anterior chamber where the device will be implanted, and the maximum allowable incision size. These factors all limit the size of the device. In addition, a novel detection scheme is required which enables detection of changes in IOP with high resolution. This paper presents the fabrication process of an ultra-small size Parylene tag in which a micro-electromechanical systems (MEMS) capacitive pressure sensor is packaged with a self-expandable Nitinol antenna and a diode. From the device implanted inside the mouse eye, a resonance frequency shift of the third-order harmonic signal was detected with a sensitivity of approximately 1.5 MHz/mmHg at an 11.5 cm distance from the sensor as the pressure inside the mouse eye changed. This work thus shows the feasibility of IOP monitoring using the third order harmonic from a device implanted inside the mouse eye.
本文展示了小鼠眼内眼压(IOP)的测量。测量设备的开发面临三个主要挑战:小鼠眼睛的大小,设备植入前房的深度,以及最大允许的切口大小。这些因素都限制了设备的尺寸。此外,需要一种新的检测方案,能够以高分辨率检测IOP的变化。本文介绍了一种超小尺寸聚对二甲苯标签的制造工艺,该标签采用微机电系统(MEMS)电容式压力传感器封装自膨胀镍钛诺天线和二极管。在植入小鼠眼内的装置上,随着小鼠眼内压力的变化,在距离传感器11.5 cm处检测到三阶谐波信号的共振频移,灵敏度约为1.5 MHz/mmHg。因此,这项工作表明了利用植入小鼠眼睛内的装置产生的三阶谐波来监测IOP的可行性。
{"title":"A compact-size packaged third-order harmonic tag for intraocular pressure (IOP) monitoring inside a mouse eye","authors":"Dohyuk Ha, Tse-Yu Lin, W. D. de Vries, Byungguk Kim, A. Chlebowski, S. John, P. Irazoqui, W. Chappell","doi":"10.1109/MWSYM.2012.6259672","DOIUrl":"https://doi.org/10.1109/MWSYM.2012.6259672","url":null,"abstract":"This paper shows measurement of intraocular pressure (IOP) within a mouse eye. Three main challenges faced the development of a device for the measurement: the size of the mouse eye, the depth of the anterior chamber where the device will be implanted, and the maximum allowable incision size. These factors all limit the size of the device. In addition, a novel detection scheme is required which enables detection of changes in IOP with high resolution. This paper presents the fabrication process of an ultra-small size Parylene tag in which a micro-electromechanical systems (MEMS) capacitive pressure sensor is packaged with a self-expandable Nitinol antenna and a diode. From the device implanted inside the mouse eye, a resonance frequency shift of the third-order harmonic signal was detected with a sensitivity of approximately 1.5 MHz/mmHg at an 11.5 cm distance from the sensor as the pressure inside the mouse eye changed. This work thus shows the feasibility of IOP monitoring using the third order harmonic from a device implanted inside the mouse eye.","PeriodicalId":6385,"journal":{"name":"2012 IEEE/MTT-S International Microwave Symposium Digest","volume":"24 1","pages":"1-3"},"PeriodicalIF":0.0,"publicationDate":"2012-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82647000","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
期刊
2012 IEEE/MTT-S International Microwave Symposium Digest
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1