首页 > 最新文献

Journal of Fire Sciences最新文献

英文 中文
Analysis of solid combustion products to establish a theoretical model of the causes of thermal runaway of ternary lithium-ion battery overcharge and heating 固体燃烧产物的分析建立三元锂离子电池过充发热热失控原因的理论模型
IF 1.9 4区 工程技术 Q2 Engineering Pub Date : 2023-01-02 DOI: 10.1177/07349041221146221
W. Liu, F. Zhao, Song Yin, Tengzhou Ma, Jiang Qing
It is difficult to determine whether ternary lithium-ion batteries (t-LIBs) were the “source” of the actual fire scene because of the little available direct evidence left after thermal runaway combustion of lithium-ion batteries (LIBs) and the lack of relevant analytical methods for t-LIBs after complete combustion. As a result, a large number of fires involving t-LIBs are controversially identified as the cause every year. In this paper, we conducted experiments on the two most common thermal runaway types of t-LIBs to investigate the correlation model between their combustion products and thermal runaway types. In the case of overcharge, the combustion products (black powder) of t-LIBs contain aluminum elements, which may be due to the thermal reaction of aluminum. In contrast, in the case of heating, the combustion products of t-LIBs have almost no detectable elemental aluminum. The reason may be due to the ability of the electrode material to continuously decompose and precipitate a large amount of metal oxides under the overcharge condition, which constitutes the condition for the occurrence of the aluminum thermal reaction, making the presence of Al2O3 in the combustion products. However, the lack of continuous current action under the heating condition prevents the generation of the aluminum thermal reaction.
由于锂离子电池(LIBs)热失控燃烧后几乎没有可用的直接证据,并且缺乏完全燃烧后t-LIBs的相关分析方法,因此很难确定三元锂离子电池是否是实际火灾现场的“来源”。因此,每年都有大量涉及t-LIBs的火灾被有争议地确定为原因。在本文中,我们对两种最常见的热失控类型的t-LIBs进行了实验,以研究其燃烧产物与热失控类型之间的相关性模型。在过度充电的情况下,t-LIBs的燃烧产物(黑色粉末)含有铝元素,这可能是由于铝的热反应。相反,在加热的情况下,t-LIBs的燃烧产物几乎没有可检测的元素铝。原因可能是电极材料在过充电条件下连续分解和沉淀大量金属氧化物的能力,这构成了铝热反应发生的条件,使得燃烧产物中存在Al2O3。然而,在加热条件下缺乏连续电流作用防止了铝热反应的产生。
{"title":"Analysis of solid combustion products to establish a theoretical model of the causes of thermal runaway of ternary lithium-ion battery overcharge and heating","authors":"W. Liu, F. Zhao, Song Yin, Tengzhou Ma, Jiang Qing","doi":"10.1177/07349041221146221","DOIUrl":"https://doi.org/10.1177/07349041221146221","url":null,"abstract":"It is difficult to determine whether ternary lithium-ion batteries (t-LIBs) were the “source” of the actual fire scene because of the little available direct evidence left after thermal runaway combustion of lithium-ion batteries (LIBs) and the lack of relevant analytical methods for t-LIBs after complete combustion. As a result, a large number of fires involving t-LIBs are controversially identified as the cause every year. In this paper, we conducted experiments on the two most common thermal runaway types of t-LIBs to investigate the correlation model between their combustion products and thermal runaway types. In the case of overcharge, the combustion products (black powder) of t-LIBs contain aluminum elements, which may be due to the thermal reaction of aluminum. In contrast, in the case of heating, the combustion products of t-LIBs have almost no detectable elemental aluminum. The reason may be due to the ability of the electrode material to continuously decompose and precipitate a large amount of metal oxides under the overcharge condition, which constitutes the condition for the occurrence of the aluminum thermal reaction, making the presence of Al2O3 in the combustion products. However, the lack of continuous current action under the heating condition prevents the generation of the aluminum thermal reaction.","PeriodicalId":15772,"journal":{"name":"Journal of Fire Sciences","volume":null,"pages":null},"PeriodicalIF":1.9,"publicationDate":"2023-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48067348","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Sensitivity analysis applied to the pyrolysis of charring and non-charring materials under a cone calorimeter 灵敏度分析应用于锥形量热计下炭化和非炭化物料的热解
IF 1.9 4区 工程技术 Q2 Engineering Pub Date : 2022-11-01 DOI: 10.1177/07349041221134486
Manon Fleurotte, O. Authier, S. Bourbigot, G. Fontaine, G. Debenest, A. Amokrane
A sensitivity analysis is performed using the Morris method to prioritize the input parameters of a pyrolysis model according to their degree of influence on the heat release rate (HRR). Moreover, this sensitivity analysis aims determining possible interactions between the input parameters. Indeed, this important aspect is original and at our best knowledge has never been studied in the past. Two materials are studied under cone calorimeter: a non-charring (poly(methyl methacrylate) (PMMA)) and a charring one (polyvinyl chloride (PVC)). Different thicknesses and external heat fluxes are studied to determine their effects on the parameters influence. With regard to PMMA, the most influent parameters are the activation energy, the emissivity, the density and the heat capacity. For the PVC, the most influent parameters are the activation energies. For the PVC, this study showed the existence of interactions between input parameters. This result is original and shows the importance of considering this in sensitivity analysis studies.
使用Morris方法进行灵敏度分析,根据热解模型的输入参数对热释放速率(HRR)的影响程度对其进行优先级排序。此外,这种灵敏度分析旨在确定输入参数之间可能的相互作用。事实上,这一重要方面是独创的,在我们看来,过去从未对其进行过研究。在锥形量热计下研究了两种材料:非炭化材料(聚甲基丙烯酸甲酯(PMMA))和炭化材料(聚氯乙烯(PVC))。研究了不同厚度和外部热通量对参数影响的影响。对于PMMA,影响最大的参数是活化能、发射率、密度和热容。对于PVC,最重要的影响参数是活化能。对于PVC,本研究表明输入参数之间存在相互作用。这一结果具有独创性,表明了在敏感性分析研究中考虑这一点的重要性。
{"title":"Sensitivity analysis applied to the pyrolysis of charring and non-charring materials under a cone calorimeter","authors":"Manon Fleurotte, O. Authier, S. Bourbigot, G. Fontaine, G. Debenest, A. Amokrane","doi":"10.1177/07349041221134486","DOIUrl":"https://doi.org/10.1177/07349041221134486","url":null,"abstract":"A sensitivity analysis is performed using the Morris method to prioritize the input parameters of a pyrolysis model according to their degree of influence on the heat release rate (HRR). Moreover, this sensitivity analysis aims determining possible interactions between the input parameters. Indeed, this important aspect is original and at our best knowledge has never been studied in the past. Two materials are studied under cone calorimeter: a non-charring (poly(methyl methacrylate) (PMMA)) and a charring one (polyvinyl chloride (PVC)). Different thicknesses and external heat fluxes are studied to determine their effects on the parameters influence. With regard to PMMA, the most influent parameters are the activation energy, the emissivity, the density and the heat capacity. For the PVC, the most influent parameters are the activation energies. For the PVC, this study showed the existence of interactions between input parameters. This result is original and shows the importance of considering this in sensitivity analysis studies.","PeriodicalId":15772,"journal":{"name":"Journal of Fire Sciences","volume":null,"pages":null},"PeriodicalIF":1.9,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46370785","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Fire-extinguishing performance and gas-phase pollution characteristics of different foam agents in extinguishing transformer oil pool fire 不同泡沫剂在变压器油池火灾中的灭火性能及气相污染特性
IF 1.9 4区 工程技术 Q2 Engineering Pub Date : 2022-11-01 DOI: 10.1177/07349041221142509
Jiaqing Zhang, Fengju Shang, Wencheng Zhou, Fei Xiao, Dengfeng Cheng
In this study, aqueous film-forming foam, fluoroprotein foam, and synthetic foam were applied to extinguish the transformer oil pool fires. The fire-extinguishing performance and burn-back resistance were investigated using a laboratory fire-extinguishing system. Moreover, the emission products were analyzed to evaluate the gas-phase pollution characteristics. Results show that aqueous film-forming foam presents the highest fire-extinguishing efficiency, while fluoroprotein foam has the best burn-back performance. Flue gas and gas chromatography–mass spectrometer analyses demonstrate that the use of fluoroprotein foam results in much higher CO emissions than other foams, and the pollutants are mainly from various hydrocarbons produced by incomplete combustion of transformer oil. Synthetic foam and aqueous film-forming foam lead to higher SO2 and NO emissions, and pollutants are mainly dominated by alcohols and ethers. Noteworthily, when using aqueous film-forming foam to extinguish oil pool fire, a persistent organic pollutant, perfluorooctanoic acid, is detected in the gas phase.
本研究采用水性成膜泡沫、氟蛋白泡沫和合成泡沫灭火变压器油池火灾。利用实验室灭火系统对其灭火性能和耐燃性进行了研究。此外,还对排放产物进行了分析,以评估气相污染特性。结果表明,水性成膜泡沫具有最高的灭火效率,而氟蛋白泡沫具有最好的回燃性能。烟气和气相色谱-质谱分析表明,氟蛋白泡沫的使用会导致比其他泡沫高得多的CO排放,污染物主要来自变压器油不完全燃烧产生的各种碳氢化合物。合成泡沫和水性成膜泡沫导致较高的SO2和NO排放,污染物主要是醇类和醚类。值得注意的是,当使用水性成膜泡沫扑灭油池火灾时,在气相中检测到一种持久性有机污染物全氟辛酸。
{"title":"Fire-extinguishing performance and gas-phase pollution characteristics of different foam agents in extinguishing transformer oil pool fire","authors":"Jiaqing Zhang, Fengju Shang, Wencheng Zhou, Fei Xiao, Dengfeng Cheng","doi":"10.1177/07349041221142509","DOIUrl":"https://doi.org/10.1177/07349041221142509","url":null,"abstract":"In this study, aqueous film-forming foam, fluoroprotein foam, and synthetic foam were applied to extinguish the transformer oil pool fires. The fire-extinguishing performance and burn-back resistance were investigated using a laboratory fire-extinguishing system. Moreover, the emission products were analyzed to evaluate the gas-phase pollution characteristics. Results show that aqueous film-forming foam presents the highest fire-extinguishing efficiency, while fluoroprotein foam has the best burn-back performance. Flue gas and gas chromatography–mass spectrometer analyses demonstrate that the use of fluoroprotein foam results in much higher CO emissions than other foams, and the pollutants are mainly from various hydrocarbons produced by incomplete combustion of transformer oil. Synthetic foam and aqueous film-forming foam lead to higher SO2 and NO emissions, and pollutants are mainly dominated by alcohols and ethers. Noteworthily, when using aqueous film-forming foam to extinguish oil pool fire, a persistent organic pollutant, perfluorooctanoic acid, is detected in the gas phase.","PeriodicalId":15772,"journal":{"name":"Journal of Fire Sciences","volume":null,"pages":null},"PeriodicalIF":1.9,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"47971045","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
The study of firefighter operation radio attenuation during fire disaster 火灾期间消防员操作无线电衰减的研究
IF 1.9 4区 工程技术 Q2 Engineering Pub Date : 2022-11-01 DOI: 10.1177/07349041221137683
C. Weng, Yuan-Ming Chiu, Ya-wen Yang
The purpose of this study is to investigate the effects of environmental and human factors on communication attenuation as well as to improve radio signal attenuation. In this study, a fire training containerized structure for firefighters and commercial rescue portable radios were used for a communication experiment in a fire scene. It was found that the firefighter’s relief communication posture reduced radio communication power. The prone posture had the greatest effect on radio communication attenuation. Also, smoke caused a decrease in communication power regardless of flame burning conditions or temperature effects. The results of the study showed that the communication power can be improved by changing the radio antenna orientation and operating the radio in a non-dense smoke layer. Finally, this study proposed that a new portable radio protection bag with thermal protection designed for firefighters wearing radios on oxygen cylinder straps could effectively improve the communication attenuation problem.
本研究旨在探讨环境与人为因素对通信衰减的影响,以改善无线电信号衰减。本研究采用消防训练集装箱结构和商用救援便携式无线电在火灾现场进行通信实验。发现消防员的救援通信姿势会降低无线电通信功率。俯卧姿势对无线电通信衰减的影响最大。此外,无论火焰燃烧条件或温度影响如何,烟雾都会导致通信功率下降。研究结果表明,通过改变无线电天线方向和在非密集烟雾层中操作无线电可以提高通信功率。最后,本研究提出了一种新型的便携式带热保护的无线电保护袋,用于在氧气瓶带上佩戴无线电的消防员,可以有效地改善通信衰减问题。
{"title":"The study of firefighter operation radio attenuation during fire disaster","authors":"C. Weng, Yuan-Ming Chiu, Ya-wen Yang","doi":"10.1177/07349041221137683","DOIUrl":"https://doi.org/10.1177/07349041221137683","url":null,"abstract":"The purpose of this study is to investigate the effects of environmental and human factors on communication attenuation as well as to improve radio signal attenuation. In this study, a fire training containerized structure for firefighters and commercial rescue portable radios were used for a communication experiment in a fire scene. It was found that the firefighter’s relief communication posture reduced radio communication power. The prone posture had the greatest effect on radio communication attenuation. Also, smoke caused a decrease in communication power regardless of flame burning conditions or temperature effects. The results of the study showed that the communication power can be improved by changing the radio antenna orientation and operating the radio in a non-dense smoke layer. Finally, this study proposed that a new portable radio protection bag with thermal protection designed for firefighters wearing radios on oxygen cylinder straps could effectively improve the communication attenuation problem.","PeriodicalId":15772,"journal":{"name":"Journal of Fire Sciences","volume":null,"pages":null},"PeriodicalIF":1.9,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43293308","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Experimental study on combustion characteristics of fire in data room 数据室火灾燃烧特性的实验研究
IF 1.9 4区 工程技术 Q2 Engineering Pub Date : 2022-08-27 DOI: 10.1177/07349041221119715
X. Gui, Haiteng Xue, Yan Jia, Can Zhang, Shi Xing
Through the combustion experiments on the cables and servers in a data room, the combustion characteristic parameters of the materials were obtained, and the materials were analyzed and evaluated from the aspects of heat release rate, gas concentration, flue gas temperature, and so on. The results show that network cable and electric cable can be ignited during the cable combustion test. In the overall fire combustion experiment of single server and the server group with three cabinets, the fire process is divided into three stages: initial growth stage, stable combustion stage, and combustion attenuation stage. The heat release rate, flue gas temperature, and CO2 concentration of the overall experiment have three peaks, respectively, 58, 98, and 134 kW; 100°C, 152°C, and 232°C; 1314, 2514, and 2988 ppm. The research results can provide some reference for design of fire protection system in data rooms.
通过对数据室中电缆和服务器的燃烧实验,获得了材料的燃烧特性参数,并从放热率、气体浓度、烟气温度等方面对材料进行了分析和评价。在单台服务器和三个机柜的服务器组的整体火灾燃烧实验中,火灾过程分为三个阶段:初始生长阶段、稳定燃烧阶段和燃烧衰减阶段。整个实验的热释放速率、烟气温度和CO2浓度分别有三个峰值,分别为58、98和134 kW;100°C、152°C和232°C;13142514和2988ppm。研究结果可为数据室消防系统的设计提供一定的参考。
{"title":"Experimental study on combustion characteristics of fire in data room","authors":"X. Gui, Haiteng Xue, Yan Jia, Can Zhang, Shi Xing","doi":"10.1177/07349041221119715","DOIUrl":"https://doi.org/10.1177/07349041221119715","url":null,"abstract":"Through the combustion experiments on the cables and servers in a data room, the combustion characteristic parameters of the materials were obtained, and the materials were analyzed and evaluated from the aspects of heat release rate, gas concentration, flue gas temperature, and so on. The results show that network cable and electric cable can be ignited during the cable combustion test. In the overall fire combustion experiment of single server and the server group with three cabinets, the fire process is divided into three stages: initial growth stage, stable combustion stage, and combustion attenuation stage. The heat release rate, flue gas temperature, and CO2 concentration of the overall experiment have three peaks, respectively, 58, 98, and 134 kW; 100°C, 152°C, and 232°C; 1314, 2514, and 2988 ppm. The research results can provide some reference for design of fire protection system in data rooms.","PeriodicalId":15772,"journal":{"name":"Journal of Fire Sciences","volume":null,"pages":null},"PeriodicalIF":1.9,"publicationDate":"2022-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43319424","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Effects of accelerated and natural weathering on fire-retarded industrial wood composite 加速和自然风化对阻燃工业木材复合材料的影响
IF 1.9 4区 工程技术 Q2 Engineering Pub Date : 2022-08-27 DOI: 10.1177/07349041221102059
G. Fontaine, V. Marchetti, S. Bourbigot
This study shows the impact of aging on the fire behavior of a fire-retarded polyvinyl chloride wood composite cladding intended for outdoor use. Two sets of composite wood cladding elements were examined: one aged naturally under exposed outdoors conditions for 1 year and the second, which underwent artificial accelerated aging. Optical microscopy, electron probe micro-analysis, and solid-state nuclear magnetic resonance of 27Al were used to investigate changes in the material properties after aging, distribution of chemical compounds, and aluminum environment. This study reveals the impact of different aging procedures on the physicochemical modifications of the composite material. In addition, after aging, the fire behavior of the two sets of composites as a function of fire exposure time was evaluated by cone calorimetry. Then, the natural aged composite was evaluated on a larger scale with the single burning item. The results surprisingly demonstrate that whatever the aging, the fire behavior of these wood composite was not affected.
本研究显示了老化对户外使用的阻燃聚氯乙烯-木材复合覆层的防火性能的影响。对两组复合木覆层元件进行了检查:一组在暴露于室外的条件下自然老化1年,另一组经过人工加速老化。利用光学显微镜、电子探针显微分析和27Al的固态核磁共振研究了材料老化后性能的变化、化合物的分布和铝环境。本研究揭示了不同老化程序对复合材料物理化学改性的影响。此外,在老化后,通过锥形量热法评估了两组复合材料的燃烧行为作为火灾暴露时间的函数。然后,用单一燃烧项目对天然老化复合材料进行了更大规模的评价。结果令人惊讶地表明,无论老化如何,这些木材复合材料的防火性能都没有受到影响。
{"title":"Effects of accelerated and natural weathering on fire-retarded industrial wood composite","authors":"G. Fontaine, V. Marchetti, S. Bourbigot","doi":"10.1177/07349041221102059","DOIUrl":"https://doi.org/10.1177/07349041221102059","url":null,"abstract":"This study shows the impact of aging on the fire behavior of a fire-retarded polyvinyl chloride wood composite cladding intended for outdoor use. Two sets of composite wood cladding elements were examined: one aged naturally under exposed outdoors conditions for 1 year and the second, which underwent artificial accelerated aging. Optical microscopy, electron probe micro-analysis, and solid-state nuclear magnetic resonance of 27Al were used to investigate changes in the material properties after aging, distribution of chemical compounds, and aluminum environment. This study reveals the impact of different aging procedures on the physicochemical modifications of the composite material. In addition, after aging, the fire behavior of the two sets of composites as a function of fire exposure time was evaluated by cone calorimetry. Then, the natural aged composite was evaluated on a larger scale with the single burning item. The results surprisingly demonstrate that whatever the aging, the fire behavior of these wood composite was not affected.","PeriodicalId":15772,"journal":{"name":"Journal of Fire Sciences","volume":null,"pages":null},"PeriodicalIF":1.9,"publicationDate":"2022-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48019945","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Electrical applications in Internet of things and e-vehicles: Passive fire safety needs and solutions 物联网和电动汽车中的电气应用:被动消防安全需求和解决方案
IF 1.9 4区 工程技术 Q2 Engineering Pub Date : 2022-07-07 DOI: 10.1177/07349041221108643
J. Troitzsch
The exponential growth of electrical devices in Internet of things and e-vehicles will lead to new fire safety challenges. As electric fires rank second among all fires and electrical equipment recalls show safety gaps, fire safety requirements must be better enforced and improved. The analysis of the current qualitative pass/fail requirements for electrotechnical products shows that they provide a basic level of fire safety. Fire testing of car and bus interiors, mandatory worldwide, is too low level. Alternative tests, such as the microscale combustion calorimeter, are discussed. Buses have to comply with additional fire tests. E-vehicles must meet a fire exposure test for electric powertrain and specifications to prevent thermal runaway of batteries. Charging stations must comply with fire and overheating requirements for enclosures, plugs, and sockets. Passive fire safety needs are primarily met by using flame retardants, and for preventing thermal runaway of batteries, by intumescent coatings, interlayers, and ceramifying products.
物联网和电动汽车中电气设备的指数级增长将带来新的消防安全挑战。由于电气火灾在所有火灾中排名第二,电气设备召回显示出安全漏洞,必须更好地执行和改进消防安全要求。对目前电工产品质量合格/不合格要求的分析表明,它们提供了基本的消防安全水平。汽车和公共汽车内饰的防火测试在世界范围内是强制性的,但水平太低。讨论了替代试验,如微尺度燃烧量热计。公共汽车必须遵守额外的防火测试。电动汽车必须通过电动动力系统的火灾暴露测试和防止电池热失控的规范。充电站必须符合外壳、插头和插座的防火和过热要求。被动防火安全需求主要通过使用阻燃剂来满足,并通过膨胀涂层、中间层和陶瓷化产品来防止电池的热失控。
{"title":"Electrical applications in Internet of things and e-vehicles: Passive fire safety needs and solutions","authors":"J. Troitzsch","doi":"10.1177/07349041221108643","DOIUrl":"https://doi.org/10.1177/07349041221108643","url":null,"abstract":"The exponential growth of electrical devices in Internet of things and e-vehicles will lead to new fire safety challenges. As electric fires rank second among all fires and electrical equipment recalls show safety gaps, fire safety requirements must be better enforced and improved. The analysis of the current qualitative pass/fail requirements for electrotechnical products shows that they provide a basic level of fire safety. Fire testing of car and bus interiors, mandatory worldwide, is too low level. Alternative tests, such as the microscale combustion calorimeter, are discussed. Buses have to comply with additional fire tests. E-vehicles must meet a fire exposure test for electric powertrain and specifications to prevent thermal runaway of batteries. Charging stations must comply with fire and overheating requirements for enclosures, plugs, and sockets. Passive fire safety needs are primarily met by using flame retardants, and for preventing thermal runaway of batteries, by intumescent coatings, interlayers, and ceramifying products.","PeriodicalId":15772,"journal":{"name":"Journal of Fire Sciences","volume":null,"pages":null},"PeriodicalIF":1.9,"publicationDate":"2022-07-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46443019","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Experiments in aerial firefighting with and without additives and its application to suppress wildfires near electrical transmission lines 有添加剂和无添加剂的空中灭火实验及其在抑制输电线路附近野火中的应用
IF 1.9 4区 工程技术 Q2 Engineering Pub Date : 2022-06-22 DOI: 10.1177/07349041221098171
Tejun Zhou, Jiazheng Lu, Lifu He, Chuanping Wu, Jing Luo
A comparison scheme is proposed to extinguish non-uniform fire scenes and continuously uniform fire scenes using a helicopter’s bucket fire-extinguishing device to spray extinguishing agent. Pure water, and Class AB, gel, and Class A extinguishing agents were added to the bucket fire-extinguishing device to spray 4-layer, 6-layer, and 12-layer wood crib fires. It was discovered that the depth (the distance from the top of the wood crib) of effective cooling and prevention of temperature recovery by extinguishing agents was 0.36 m and that the cooling performance of the extinguishing agents in sequence from high to low was Class A extinguishing agent > gel extinguishing agent > Class AB extinguishing agent > pure water. Their capacity to prevent temperature recovery in the wood crib fires in sequence from high to low was gel extinguishing agent > Class A extinguishing agent > Class AB extinguishing agent > pure water. A device has been developed that can add extinguishing agent to the helicopter bucket efficiently, and its application on-site during the 2020–2021 Spring Festival and other events showed that it can quickly extinguish small-area wildfires near electrical transmission lines to reduce line trips due to wildfire.
提出了利用直升机桶式灭火装置喷淋灭火剂扑灭非均匀火场和连续均匀火场的比较方案。在桶式灭火装置中加入纯净水、AB类、凝胶、A类灭火剂,分别喷洒4层、6层、12层木床火灾。发现灭火剂有效冷却和防止温度恢复的深度(距木槽顶部的距离)为0.36 m,灭火剂的冷却性能从高到低依次为A类灭火剂>凝胶灭火剂> AB类灭火剂>纯水。它们在木槽火灾中防止温度恢复的能力从高到低依次为凝胶灭火剂> A类灭火剂> AB类灭火剂>纯水。研制了一种高效向直升机铲斗中添加灭火剂的装置,并在2020-2021年春节等活动的现场应用表明,该装置可以快速扑灭输电线路附近的小区域野火,减少因野火导致的线路跳闸。
{"title":"Experiments in aerial firefighting with and without additives and its application to suppress wildfires near electrical transmission lines","authors":"Tejun Zhou, Jiazheng Lu, Lifu He, Chuanping Wu, Jing Luo","doi":"10.1177/07349041221098171","DOIUrl":"https://doi.org/10.1177/07349041221098171","url":null,"abstract":"A comparison scheme is proposed to extinguish non-uniform fire scenes and continuously uniform fire scenes using a helicopter’s bucket fire-extinguishing device to spray extinguishing agent. Pure water, and Class AB, gel, and Class A extinguishing agents were added to the bucket fire-extinguishing device to spray 4-layer, 6-layer, and 12-layer wood crib fires. It was discovered that the depth (the distance from the top of the wood crib) of effective cooling and prevention of temperature recovery by extinguishing agents was 0.36 m and that the cooling performance of the extinguishing agents in sequence from high to low was Class A extinguishing agent > gel extinguishing agent > Class AB extinguishing agent > pure water. Their capacity to prevent temperature recovery in the wood crib fires in sequence from high to low was gel extinguishing agent > Class A extinguishing agent > Class AB extinguishing agent > pure water. A device has been developed that can add extinguishing agent to the helicopter bucket efficiently, and its application on-site during the 2020–2021 Spring Festival and other events showed that it can quickly extinguish small-area wildfires near electrical transmission lines to reduce line trips due to wildfire.","PeriodicalId":15772,"journal":{"name":"Journal of Fire Sciences","volume":null,"pages":null},"PeriodicalIF":1.9,"publicationDate":"2022-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"47963876","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Flame retardancy of biodegradable polylactic acid with piperazine pyrophosphate and melamine cyanurate as flame retardant 以焦磷酸哌嗪和三聚氰胺为阻燃剂的可生物降解聚乳酸的阻燃性能
IF 1.9 4区 工程技术 Q2 Engineering Pub Date : 2022-05-08 DOI: 10.1177/07349041221093546
Hongxu Chen, Wei Xia, Nan Wang, Yang Liu, Penghui Fan, Song Wang, Sanxi Li, Jie Liu, Tao Tang, Ailing Zhang, Zhan Ding, Wei Wu, Qi Chen
A flame-retardant polylactic acid composite added with piperazine pyrophosphate and melamine cyanurate was developed. Piperazine pyrophosphate and melamine cyanurate showed synergistic effect in the polylactic acid composites. When the weight ratio of piperazine pyrophosphate to melamine cyanurate was 4:1 and the loading of the piperazine pyrophosphate/melamine cyanurate flame retardant was 15 wt.%, the prepared polylactic acid composites passed V-0 rating in the UL-94 test and achieved the high limit oxygen index value of 34.9%. The cone calorimeter test result confirmed that the addition of piperazine pyrophosphate/melamine cyanurate flame retardant reduced the total heat release value of polylactic acid. The effect of polylactic acid biodegradation on the flame retardancy of polylactic acid composite was further discussed. The biodegraded polylactic acid, which was exposed to the air for 8 months, showed high flame retardancy and even passed V-0 rating in the UL-94 test without the addition of piperazine pyrophosphate/melamine cyanurate flame retardant, which proved that biodegradation could affect the flame retardancy of polylactic acid.
以焦磷酸哌嗪和氰尿酸三聚氰胺为原料,研制了阻燃聚乳酸复合材料。焦磷酸哌嗪和氰尿酸三聚氰胺在聚乳酸复合材料中表现出协同作用。当焦磷酸哌嗪与氰尿酸三聚氰胺的重量比为4:1,焦磷酸哌津/氰尿酸三聚氰胺阻燃剂的负载量为15时 所制备的聚乳酸复合材料在UL-94测试中通过了V-0评级,并获得了34.9%的高极限氧指数值。锥形量热计测试结果证实,焦磷酸哌嗪/三聚氰胺氰尿酸盐阻燃剂的加入降低了聚乳酸的总放热值。进一步讨论了聚乳酸生物降解对聚乳酸复合材料阻燃性能的影响。生物降解的聚乳酸,暴露在空气中8 月,在不添加焦磷酸哌嗪/三聚氰胺氰尿酸盐阻燃剂的情况下,在UL-94测试中显示出高阻燃性,甚至通过了V-0评级,这证明生物降解会影响聚乳酸的阻燃性。
{"title":"Flame retardancy of biodegradable polylactic acid with piperazine pyrophosphate and melamine cyanurate as flame retardant","authors":"Hongxu Chen, Wei Xia, Nan Wang, Yang Liu, Penghui Fan, Song Wang, Sanxi Li, Jie Liu, Tao Tang, Ailing Zhang, Zhan Ding, Wei Wu, Qi Chen","doi":"10.1177/07349041221093546","DOIUrl":"https://doi.org/10.1177/07349041221093546","url":null,"abstract":"A flame-retardant polylactic acid composite added with piperazine pyrophosphate and melamine cyanurate was developed. Piperazine pyrophosphate and melamine cyanurate showed synergistic effect in the polylactic acid composites. When the weight ratio of piperazine pyrophosphate to melamine cyanurate was 4:1 and the loading of the piperazine pyrophosphate/melamine cyanurate flame retardant was 15 wt.%, the prepared polylactic acid composites passed V-0 rating in the UL-94 test and achieved the high limit oxygen index value of 34.9%. The cone calorimeter test result confirmed that the addition of piperazine pyrophosphate/melamine cyanurate flame retardant reduced the total heat release value of polylactic acid. The effect of polylactic acid biodegradation on the flame retardancy of polylactic acid composite was further discussed. The biodegraded polylactic acid, which was exposed to the air for 8 months, showed high flame retardancy and even passed V-0 rating in the UL-94 test without the addition of piperazine pyrophosphate/melamine cyanurate flame retardant, which proved that biodegradation could affect the flame retardancy of polylactic acid.","PeriodicalId":15772,"journal":{"name":"Journal of Fire Sciences","volume":null,"pages":null},"PeriodicalIF":1.9,"publicationDate":"2022-05-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48821296","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 17
The well-meaning but misguided rollback of fire safety in the United States 美国消防安全善意但被误导的倒退
IF 1.9 4区 工程技术 Q2 Engineering Pub Date : 2022-05-04 DOI: 10.1177/07349041221096609
A. Morgan
{"title":"The well-meaning but misguided rollback of fire safety in the United States","authors":"A. Morgan","doi":"10.1177/07349041221096609","DOIUrl":"https://doi.org/10.1177/07349041221096609","url":null,"abstract":"","PeriodicalId":15772,"journal":{"name":"Journal of Fire Sciences","volume":null,"pages":null},"PeriodicalIF":1.9,"publicationDate":"2022-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46300111","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Journal of Fire Sciences
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1