Purpose The purpose of this study is solving the hand–eye calibration issue for line structured light vision sensor. Only after hand–eye calibration the sensor measurement data can be applied to robot system. Design/methodology/approach In this paper, the hand–eye calibration methods are studied, respectively, for eye-in-hand and eye-to-hand. Firstly, the coordinates of the target point in robot system are obtained by tool centre point (TCP), then the robot is controlled to make the sensor measure the target point in multiple poses and the measurement data and pose data are obtained; finally, the sum of squared calibration errors is minimized by the least square method. Furthermore, the missing vector in the process of solving the transformation matrix is obtained by vector operation, and the complete matrix is obtained. Findings On this basis, the sensor measurement data can be easily and accurately converted to the robot coordinate system by matrix operation. Originality/value This method has no special requirement for robot pose control, and its calibration process is fast and efficient, with high precision and has practical popularized value.
{"title":"A novel hand-eye calibration method for industrial robot and line laser vision sensor","authors":"Xu Jingbo, Li Qiaowei, White Bai","doi":"10.1108/sr-09-2022-0357","DOIUrl":"https://doi.org/10.1108/sr-09-2022-0357","url":null,"abstract":"\u0000Purpose\u0000The purpose of this study is solving the hand–eye calibration issue for line structured light vision sensor. Only after hand–eye calibration the sensor measurement data can be applied to robot system.\u0000\u0000\u0000Design/methodology/approach\u0000In this paper, the hand–eye calibration methods are studied, respectively, for eye-in-hand and eye-to-hand. Firstly, the coordinates of the target point in robot system are obtained by tool centre point (TCP), then the robot is controlled to make the sensor measure the target point in multiple poses and the measurement data and pose data are obtained; finally, the sum of squared calibration errors is minimized by the least square method. Furthermore, the missing vector in the process of solving the transformation matrix is obtained by vector operation, and the complete matrix is obtained.\u0000\u0000\u0000Findings\u0000On this basis, the sensor measurement data can be easily and accurately converted to the robot coordinate system by matrix operation.\u0000\u0000\u0000Originality/value\u0000This method has no special requirement for robot pose control, and its calibration process is fast and efficient, with high precision and has practical popularized value.\u0000","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":" ","pages":""},"PeriodicalIF":1.6,"publicationDate":"2023-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48739007","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Ling Weng, Zhuolin Li, Xu Luo, Yuanye Zhang, Yang Liu
Purpose This paper aims to design a magnetostrictive tactile sensor for surface depth detection. Unlike the human finger, although most tactile sensors have high sensitivity to pressure, they cannot detect millimeter-level depth information on the surface of objects precisely. To enhance the ability to detect surface depth information, a piezomagnetic sensor combining inverse magnetostrictive effect and bionic structure is developed in this paper. Design/methodology/approach A magnetostrictive tactile sensor based on Galfenol [(Fe83Ga17)99.4B0.6] is designed and studied for surface depth measurement. The optimal structure of the sensor is determined by experiment and theory. The test platforms for static and dynamic characteristics are set up. The static and the dynamic sensing performance of the sensor are studied experimentally. Findings The sensor can detect 0–2 mm depth change with a sensitivity of 91.5 mV/mm. A resolution of 50 µm can be achieved in the depth direction. In 50 cycles of loading and unloading tests, the maximum error of the sensor output voltage amplitude is only 2.23%. Originality/value The sensor can measure the depth information of object surface precisely with good repeatability through sliding motion and provide reference for object surface topography detection.
{"title":"Design of magnetostrictive tactile sensor for depth detection","authors":"Ling Weng, Zhuolin Li, Xu Luo, Yuanye Zhang, Yang Liu","doi":"10.1108/sr-01-2022-0051","DOIUrl":"https://doi.org/10.1108/sr-01-2022-0051","url":null,"abstract":"\u0000Purpose\u0000This paper aims to design a magnetostrictive tactile sensor for surface depth detection. Unlike the human finger, although most tactile sensors have high sensitivity to pressure, they cannot detect millimeter-level depth information on the surface of objects precisely. To enhance the ability to detect surface depth information, a piezomagnetic sensor combining inverse magnetostrictive effect and bionic structure is developed in this paper.\u0000\u0000\u0000Design/methodology/approach\u0000A magnetostrictive tactile sensor based on Galfenol [(Fe83Ga17)99.4B0.6] is designed and studied for surface depth measurement. The optimal structure of the sensor is determined by experiment and theory. The test platforms for static and dynamic characteristics are set up. The static and the dynamic sensing performance of the sensor are studied experimentally.\u0000\u0000\u0000Findings\u0000The sensor can detect 0–2 mm depth change with a sensitivity of 91.5 mV/mm. A resolution of 50 µm can be achieved in the depth direction. In 50 cycles of loading and unloading tests, the maximum error of the sensor output voltage amplitude is only 2.23%.\u0000\u0000\u0000Originality/value\u0000The sensor can measure the depth information of object surface precisely with good repeatability through sliding motion and provide reference for object surface topography detection.\u0000","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":" ","pages":""},"PeriodicalIF":1.6,"publicationDate":"2023-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45558257","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Purpose In this investigation, a linear encoder system based on the ultrasonic transducer has been proposed. Ultrasonic transducers are usually designed for distance measurements, such as the time of flight method and sonar system. These applications are defined as discrete-length measurement technologies. The purpose of this study is to develop a continuous displacement measurement system using ultrasonic transducers. Design/methodology/approach A modified signal processing based on heterodyne signaling is implemented in this system. In the proposed signal processing, there is an automatic gain control module, a phase-shifting module, a phase detection module, an interpolation module and especially a frequency multiplication module, which can enhance the resolution and reduce the interpolation error simultaneously. Findings The proposed system can generate the encoding signals and is compatible with most motion control systems. For the experimental result, the maximum measurement error and standard deviation are about −0.027 and 0.048 mm, respectively. It shows that the proposed encoder system has the potential for displacement measurement tasks. Originality/value This study reveals an ultrasonic linear encoder that is capable of generating an incremental encoding signal, accompanied by a corresponding signal processing methodology. In contrast to the conventional heterodyne signal processing approach, the proposed multiplication method effectively reduces the interpolation error that arises because of multiple reflections.
{"title":"Development of an ultrasonic linear encoder","authors":"Chung-Ping Chang, Song-Fu Hong, Tzu-Guang Chen","doi":"10.1108/sr-07-2022-0262","DOIUrl":"https://doi.org/10.1108/sr-07-2022-0262","url":null,"abstract":"\u0000Purpose\u0000In this investigation, a linear encoder system based on the ultrasonic transducer has been proposed. Ultrasonic transducers are usually designed for distance measurements, such as the time of flight method and sonar system. These applications are defined as discrete-length measurement technologies. The purpose of this study is to develop a continuous displacement measurement system using ultrasonic transducers.\u0000\u0000\u0000Design/methodology/approach\u0000A modified signal processing based on heterodyne signaling is implemented in this system. In the proposed signal processing, there is an automatic gain control module, a phase-shifting module, a phase detection module, an interpolation module and especially a frequency multiplication module, which can enhance the resolution and reduce the interpolation error simultaneously.\u0000\u0000\u0000Findings\u0000The proposed system can generate the encoding signals and is compatible with most motion control systems. For the experimental result, the maximum measurement error and standard deviation are about −0.027 and 0.048 mm, respectively. It shows that the proposed encoder system has the potential for displacement measurement tasks.\u0000\u0000\u0000Originality/value\u0000This study reveals an ultrasonic linear encoder that is capable of generating an incremental encoding signal, accompanied by a corresponding signal processing methodology. In contrast to the conventional heterodyne signal processing approach, the proposed multiplication method effectively reduces the interpolation error that arises because of multiple reflections.\u0000","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":" ","pages":""},"PeriodicalIF":1.6,"publicationDate":"2023-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"47330676","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Purpose Ubiquitous health-care monitoring systems can provide continuous surveillance to a person using various sensors, including wearables and implantable and fabric-woven sensors. By assessing the state of many physiological characteristics of the patient’s body, continuous monitoring can assist in preparing for the impending emergency. To address this issue, this study aims to propose a health-care system that integrates the treatment of the impending heart, stress and alcohol emergencies. For this purpose, this study uses readings from sensors used for electrocardiography, heart rate, respiration rate, blood alcohol content percentage and blood pressure of a patient’s body. Design/methodology/approach For heart status, stress level and alcohol detection, the parametric values obtained from these sensors are preprocessed and further divided into four, five and six phases, respectively. A final integrated emergency stage is derived from the stages that were interpreted to examine at a person’s state of emergency. A thorough analysis of the proposed model is carried out using four classification techniques, including decision trees, support vector machines, k nearest neighbors and ensemble classifiers. For all of the aforementioned detections, four metrics are used to evaluate performance: classification accuracy, precision, recall and fmeasure. Findings Eventually, results are validated against the existing health-care systems. The empirical results received reveal that the proposed model outperforms the existing health-care models in the context of metrics above for different detections taken into consideration. Originality/value This study proposes a health-care system capable of performing data processing using wearable sensors. It is of great importance for real-time systems. This study assures the originality of the proposed system.
{"title":"A multi-sensor based emergency healthcare monitoring system integrating heart status, stress, and alcohol detections","authors":"Karandeep Kaur, H. Verma","doi":"10.1108/sr-03-2022-0136","DOIUrl":"https://doi.org/10.1108/sr-03-2022-0136","url":null,"abstract":"\u0000Purpose\u0000Ubiquitous health-care monitoring systems can provide continuous surveillance to a person using various sensors, including wearables and implantable and fabric-woven sensors. By assessing the state of many physiological characteristics of the patient’s body, continuous monitoring can assist in preparing for the impending emergency. To address this issue, this study aims to propose a health-care system that integrates the treatment of the impending heart, stress and alcohol emergencies. For this purpose, this study uses readings from sensors used for electrocardiography, heart rate, respiration rate, blood alcohol content percentage and blood pressure of a patient’s body.\u0000\u0000\u0000Design/methodology/approach\u0000For heart status, stress level and alcohol detection, the parametric values obtained from these sensors are preprocessed and further divided into four, five and six phases, respectively. A final integrated emergency stage is derived from the stages that were interpreted to examine at a person’s state of emergency. A thorough analysis of the proposed model is carried out using four classification techniques, including decision trees, support vector machines, k nearest neighbors and ensemble classifiers. For all of the aforementioned detections, four metrics are used to evaluate performance: classification accuracy, precision, recall and fmeasure.\u0000\u0000\u0000Findings\u0000Eventually, results are validated against the existing health-care systems. The empirical results received reveal that the proposed model outperforms the existing health-care models in the context of metrics above for different detections taken into consideration.\u0000\u0000\u0000Originality/value\u0000This study proposes a health-care system capable of performing data processing using wearable sensors. It is of great importance for real-time systems. This study assures the originality of the proposed system.\u0000","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":" ","pages":""},"PeriodicalIF":1.6,"publicationDate":"2023-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43057481","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Purpose Flexible pressure sensor arrays have promising applications in analog haptics, reconfiguration of sensory functions, artificial intelligence, wearable devices and human-computer interaction. The force disturbance generated by the connecting material between the sensor array units will reduce the detection accuracy of the unit. The purpose of this paper is to propose a flexible pressure sensor with interference immunity capability. A C-type bridge flexible piezoelectric structure is used to improve the pressure perturbation. The interference immunity capability of the sensor has been improved. Design/methodology/approach In this paper, a C-type pressure sensor array structure by rapid injection moulding is manufactured through the positive piezoelectric effect of a piezoelectric material. The feasibility of C-type interference immunity structure in a flexible sensor array is verified by further analysis and experiment. A flexible pressure sensor array with C-type interference immunity structure has been proposed. Findings In this paper, we present the results of the perturbation experiment results of the C-type pressure sensor array, showing that the perturbation error is less than 8%. The test of the flexible sensor array show that the sensor can identify the curved angle of up to 120 °, and the output sensitivity of the sensor in the horizontal state reaches 0.12 V/N, and the sensor can withstand the pressure of 80 N. The flexible sensor can work stably in the stretch rate range of 0–8.6% and the stretch length range of 0–6 mm. Originality/value In this paper, C-type pressure sensor array structure is fabricated by rapid injection moulding for the first time. The research in this paper can effectively reduce the disturbance of input pressure on the sensor’s internal array and improve the output accuracy. The sensor can intuitively reflect the number of fingers sliding on the sensor by the order in which the maximum voltage appears. Due to the strong interference immunity capability and flexibility of the flexible sensor array mechanism, it has a broad application prospect in the practical fields of haptic simulation, perceptual function reconstruction, artificial intelligence, wearable devices and human–computer interaction.
{"title":"A flexible pressure sensor with interference immunity capability","authors":"Huan Liu, Rui Wang, Junyao Wang, Xingyu Chen, Yunpeng Li, Bowen Cui, Tianhong Lang, Weihua Zhu","doi":"10.1108/sr-12-2021-0487","DOIUrl":"https://doi.org/10.1108/sr-12-2021-0487","url":null,"abstract":"\u0000Purpose\u0000Flexible pressure sensor arrays have promising applications in analog haptics, reconfiguration of sensory functions, artificial intelligence, wearable devices and human-computer interaction. The force disturbance generated by the connecting material between the sensor array units will reduce the detection accuracy of the unit. The purpose of this paper is to propose a flexible pressure sensor with interference immunity capability. A C-type bridge flexible piezoelectric structure is used to improve the pressure perturbation. The interference immunity capability of the sensor has been improved.\u0000\u0000\u0000Design/methodology/approach\u0000In this paper, a C-type pressure sensor array structure by rapid injection moulding is manufactured through the positive piezoelectric effect of a piezoelectric material. The feasibility of C-type interference immunity structure in a flexible sensor array is verified by further analysis and experiment. A flexible pressure sensor array with C-type interference immunity structure has been proposed.\u0000\u0000\u0000Findings\u0000In this paper, we present the results of the perturbation experiment results of the C-type pressure sensor array, showing that the perturbation error is less than 8%. The test of the flexible sensor array show that the sensor can identify the curved angle of up to 120 °, and the output sensitivity of the sensor in the horizontal state reaches 0.12 V/N, and the sensor can withstand the pressure of 80 N. The flexible sensor can work stably in the stretch rate range of 0–8.6% and the stretch length range of 0–6 mm.\u0000\u0000\u0000Originality/value\u0000In this paper, C-type pressure sensor array structure is fabricated by rapid injection moulding for the first time. The research in this paper can effectively reduce the disturbance of input pressure on the sensor’s internal array and improve the output accuracy. The sensor can intuitively reflect the number of fingers sliding on the sensor by the order in which the maximum voltage appears. Due to the strong interference immunity capability and flexibility of the flexible sensor array mechanism, it has a broad application prospect in the practical fields of haptic simulation, perceptual function reconstruction, artificial intelligence, wearable devices and human–computer interaction.\u0000","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":" ","pages":""},"PeriodicalIF":1.6,"publicationDate":"2023-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45372963","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Purpose This paper aims to study the influence of different reinforcement methods on crack monitoring characteristics of eddy current array sensors, and the sensors with two different reinforcement methods, SUS304 reinforcement and permalloy reinforcement, are proposed. Design/methodology/approach First, the finite element model of the sensor is established to analyze the influence of the reinforcement plate’s electromagnetic parameters on the crack identification sensitivity. Then, the crack monitoring accuracy test of sensors with two reinforcement methods is carried out. Finally, the fatigue crack monitoring experiments with bolt tightening torques of 45 and 63 N · m are carried out, respectively. Findings In this study, it is found that the crack identification sensitivity of the sensor can be improved by increasing the relative permeability of the reinforcement plate. The crack monitoring accuracy of the sensors with two different reinforcement methods is about 1 mm. And the crack identification sensitivity of the sensor reinforced by permalloy reinforcement plate is significantly higher than that of the sensor reinforced by SUS304 reinforcement plate. Originality/value The sensor reinforced by reinforcement plate can work normally under the squeezing action of the bolt, and the crack monitoring sensitivity of the sensor can be significantly improved by using the reinforcement plate with high relative permeability.
{"title":"Comparison of different reinforcement methods on crack monitoring characteristics of eddy current array sensor","authors":"Xianghong Fan, Tao Chen, Yuting He","doi":"10.1108/sr-09-2022-0355","DOIUrl":"https://doi.org/10.1108/sr-09-2022-0355","url":null,"abstract":"\u0000Purpose\u0000This paper aims to study the influence of different reinforcement methods on crack monitoring characteristics of eddy current array sensors, and the sensors with two different reinforcement methods, SUS304 reinforcement and permalloy reinforcement, are proposed.\u0000\u0000\u0000Design/methodology/approach\u0000First, the finite element model of the sensor is established to analyze the influence of the reinforcement plate’s electromagnetic parameters on the crack identification sensitivity. Then, the crack monitoring accuracy test of sensors with two reinforcement methods is carried out. Finally, the fatigue crack monitoring experiments with bolt tightening torques of 45 and 63 N · m are carried out, respectively.\u0000\u0000\u0000Findings\u0000In this study, it is found that the crack identification sensitivity of the sensor can be improved by increasing the relative permeability of the reinforcement plate. The crack monitoring accuracy of the sensors with two different reinforcement methods is about 1 mm. And the crack identification sensitivity of the sensor reinforced by permalloy reinforcement plate is significantly higher than that of the sensor reinforced by SUS304 reinforcement plate.\u0000\u0000\u0000Originality/value\u0000The sensor reinforced by reinforcement plate can work normally under the squeezing action of the bolt, and the crack monitoring sensitivity of the sensor can be significantly improved by using the reinforcement plate with high relative permeability.\u0000","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":" ","pages":""},"PeriodicalIF":1.6,"publicationDate":"2023-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43240744","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
D. H. A. Nascimento, F. Magalhães, G. Sabino, R. Resende, M. Duarte, Claysson Bruno Santos Vimieiro
Purpose Currently, several studies have been published using sensorized insoles for estimating ground reaction force using plantar pressure. However, information on design parameters, manufacturing techniques and guidelines for developing insoles is scarce, often leaving gaps that do not allow reproducing the insole. This study aims to empirically investigate the main parameters of constructing a sensorized insole for application in human gait. Design/methodology/approach Two devices were built to evaluate the force sensors. The first focuses on the construction of the sensors with different settings: the density of the sensor’s conductive trails (thickness and distance of the trails) and the inertia of the sensors (use of spacers to prevent unwanted readings). The second device focuses on the data capture and processing system: resolution of the analog–digital converter, acquisition rate and sensor activation level. Findings The resolution increase of the analog–digital converter and acquisition rate do not contribute to noise increase. Reducing the sensors’ coverage area can increase sensorized insole capacity. The inertia of the sensors can be adjusted using spacers without changing the electrical circuit and acquisition system. Originality/value Most sensorized insoles use commercial sensors. For this reason, it is not possible a full customization. This paper maps the main variables to manufacture custom sensors and data acquisition systems. This work also presents a case study where it is possible to see the influence of the parameters in the correlation between the sensorized insole and an instrumented treadmill with a force platform.
{"title":"Design a custom resistive force sensors to optimize sensorized insoles","authors":"D. H. A. Nascimento, F. Magalhães, G. Sabino, R. Resende, M. Duarte, Claysson Bruno Santos Vimieiro","doi":"10.1108/sr-08-2022-0322","DOIUrl":"https://doi.org/10.1108/sr-08-2022-0322","url":null,"abstract":"\u0000Purpose\u0000Currently, several studies have been published using sensorized insoles for estimating ground reaction force using plantar pressure. However, information on design parameters, manufacturing techniques and guidelines for developing insoles is scarce, often leaving gaps that do not allow reproducing the insole. This study aims to empirically investigate the main parameters of constructing a sensorized insole for application in human gait.\u0000\u0000\u0000Design/methodology/approach\u0000Two devices were built to evaluate the force sensors. The first focuses on the construction of the sensors with different settings: the density of the sensor’s conductive trails (thickness and distance of the trails) and the inertia of the sensors (use of spacers to prevent unwanted readings). The second device focuses on the data capture and processing system: resolution of the analog–digital converter, acquisition rate and sensor activation level.\u0000\u0000\u0000Findings\u0000The resolution increase of the analog–digital converter and acquisition rate do not contribute to noise increase. Reducing the sensors’ coverage area can increase sensorized insole capacity. The inertia of the sensors can be adjusted using spacers without changing the electrical circuit and acquisition system.\u0000\u0000\u0000Originality/value\u0000Most sensorized insoles use commercial sensors. For this reason, it is not possible a full customization. This paper maps the main variables to manufacture custom sensors and data acquisition systems. This work also presents a case study where it is possible to see the influence of the parameters in the correlation between the sensorized insole and an instrumented treadmill with a force platform.\u0000","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":" ","pages":""},"PeriodicalIF":1.6,"publicationDate":"2023-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"47466323","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Purpose The noise measurement on magnetoresistive (MR) sensors is generally conducted by techniques including single-channel data sampling and fast Fourier transform (FFT) analysis as well as two-channel cross-correlation. The single-channel method is easy to implement and is widely used in the noise measurement on MR sensors, whereas the two-channel method can only eliminate part of the system noise. This study aims to address two key issues affecting measurement accuracy: calibration of the measurement system and the elimination of system noise. Design/methodology/approach The system is calibrated by using a low-noise metal film resistor in that the system noise is eliminated through power spectrum subtraction. Noise measurement and analysis are conducted for both thermal noise and detectivity of magnetic tunnel junction (MTJ) sensor. Findings The thermal noise measurement error is less than 2%. The detectivity of the MTJ sensor reaches 27 pT/Hz1/2 at 2 kHz. Originality/value This study provides a more practical solution for noise measurement and system calibration on MR sensors with a bias voltage and magnetic field.
{"title":"Noise measurement and system calibration on magnetoresistive sensors","authors":"Aiyu Dou, R. Bai, Huachen Zhu, Z. Qian","doi":"10.1108/sr-07-2022-0284","DOIUrl":"https://doi.org/10.1108/sr-07-2022-0284","url":null,"abstract":"\u0000Purpose\u0000The noise measurement on magnetoresistive (MR) sensors is generally conducted by techniques including single-channel data sampling and fast Fourier transform (FFT) analysis as well as two-channel cross-correlation. The single-channel method is easy to implement and is widely used in the noise measurement on MR sensors, whereas the two-channel method can only eliminate part of the system noise. This study aims to address two key issues affecting measurement accuracy: calibration of the measurement system and the elimination of system noise.\u0000\u0000\u0000Design/methodology/approach\u0000The system is calibrated by using a low-noise metal film resistor in that the system noise is eliminated through power spectrum subtraction. Noise measurement and analysis are conducted for both thermal noise and detectivity of magnetic tunnel junction (MTJ) sensor.\u0000\u0000\u0000Findings\u0000The thermal noise measurement error is less than 2%. The detectivity of the MTJ sensor reaches 27 pT/Hz1/2 at 2 kHz.\u0000\u0000\u0000Originality/value\u0000This study provides a more practical solution for noise measurement and system calibration on MR sensors with a bias voltage and magnetic field.\u0000","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":"1 1","pages":""},"PeriodicalIF":1.6,"publicationDate":"2023-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41726330","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Purpose The purpose of this study is to clarify the mechanism of ambient and transient temperature effects on piezoelectric pressure sensors, and to propose corresponding compensation measures. The temperature of the explosion field has a significant influence on the piezoelectric sensor used to measure the shock wave pressure. For accurate shock wave pressure measurement, based on the actual piezoelectric pressure sensors used in the explosion field, the effects of ambient and transient temperatures on the sensor should be studied. Design/methodology/approach The compensation method of the ambient temperature is discussed according to the sensor size and material. The theoretical analysis method of the transient temperature is proposed. For the transient temperature conduction problem of the sensor, the finite element simulation method of structure-temperature coupling is used to solve the temperature distribution of the sensor and the change in the contact force on the quartz crystal surface under the step and triangle temperatures. The simulation results are highly consistent with the theory. Findings Based on the analysis results, a transient temperature control method is proposed, in which 0.5 mm thick lubricating silicone grease is applied to the sensor diaphragm, and 0.2 mm thick fiberglass cloth is wrapped around the sensor side. Simulation experiments are carried out to verify the feasibility of the control method, and the results show that the control method effectively suppresses the output of the thermal parasitic. Originality/value The above thermal protection methods can effectively improve the measurement accuracy of shock wave pressure and provide technical support for the evaluation of the power of explosion damage.
{"title":"Research on thermal protection of piezoelectric pressure sensor for shock wave pressure measurement in explosion field","authors":"Yucheng Shi, D. Kong, Xuejiao Ma","doi":"10.1108/sr-11-2022-0407","DOIUrl":"https://doi.org/10.1108/sr-11-2022-0407","url":null,"abstract":"\u0000Purpose\u0000The purpose of this study is to clarify the mechanism of ambient and transient temperature effects on piezoelectric pressure sensors, and to propose corresponding compensation measures. The temperature of the explosion field has a significant influence on the piezoelectric sensor used to measure the shock wave pressure. For accurate shock wave pressure measurement, based on the actual piezoelectric pressure sensors used in the explosion field, the effects of ambient and transient temperatures on the sensor should be studied.\u0000\u0000\u0000Design/methodology/approach\u0000The compensation method of the ambient temperature is discussed according to the sensor size and material. The theoretical analysis method of the transient temperature is proposed. For the transient temperature conduction problem of the sensor, the finite element simulation method of structure-temperature coupling is used to solve the temperature distribution of the sensor and the change in the contact force on the quartz crystal surface under the step and triangle temperatures. The simulation results are highly consistent with the theory.\u0000\u0000\u0000Findings\u0000Based on the analysis results, a transient temperature control method is proposed, in which 0.5 mm thick lubricating silicone grease is applied to the sensor diaphragm, and 0.2 mm thick fiberglass cloth is wrapped around the sensor side. Simulation experiments are carried out to verify the feasibility of the control method, and the results show that the control method effectively suppresses the output of the thermal parasitic.\u0000\u0000\u0000Originality/value\u0000The above thermal protection methods can effectively improve the measurement accuracy of shock wave pressure and provide technical support for the evaluation of the power of explosion damage.\u0000","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":" ","pages":""},"PeriodicalIF":1.6,"publicationDate":"2023-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41812848","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Purpose Piperidine side chain-functionalized N, N′-bissalicylidene phenylene di amine di-anion (salphen) consisting of salphen-Zn and salphen-Cu are able to intercalate with nucleic base stacking of DNA and can be applied as an optical DNA hybridization detector. Attaching DNA and salphen to glass surfaces has been done via coating the surface with the silane coupling agents containing 3-aminopropyltriethoxysilane that was synthesized for acting as a high-affinity RNA carrier matrix. The Schiff base salphen-zinc (II) and salphen-Cu (II) complexes-labelled probe to target nucleic acid renders a colour change of the DNA biosensor to a green and red background colour for zinc and copper, respectively. This study aims to indicate that the DNA biosensor data with high efficiency is used for detection of dengue virus serotypes 2 (DENV-2) and Chikungunya virus (CHIKV) concentration via salphen-Zn (II) and salphen-Cu (II), respectively, in human samples. Design/methodology/approach 1H-NMR and 13C-NMR have been used via PerkinElmer LAMBDA 35 instrument. The authors also used a double beam spectrophotometer with (CH3)4Si (TMS) as reference and dimethyl sulfoxide as solvent reference in pH = 7.0. Various DNA concentrations have been used for UV spectrophotometry at 300 nm and 400 nm for zinc and copper complexes, respectively. BRUKER mass spectra with DIONEX Ultimate 3000 LC model were used for all measurements. Mettler Teledo model (DSC882e) of differential scanning calorimeter (DSC) was used for measure the melting temperature of metal zinc and copper complexes. The morphology of the silica Nano spheres (SiNs) were scanned by FESEM with Model JSM-6700F from Japan. Findings The Cu (II) and Zn (II)-salphen-viruses DNA system for CHIKV and DENV-2, respectively, in different concentration have been investigated via various spectroscopies (Figure 3). CHIKV and DENV-2 DNA were selected from human saliva and urine samples as models for conformations of human G4-DNA. By increasing the amounts of DNAs, and G4, the UV–Vis bands of located above 300 nm, experienced a hypochromic effect. The Cu2+ complex exhibits selectivity towards the G4, and there is a similar affinity for Zn2+ complex binds to the G4. These results collectively suggest that the Cu2+ complex is stronger than the Zn2+ complex. The authors have found copper (II) and zinc (II) compounds and nucleic acid-complexes are strongly fluorescent molecules in the low energy range, from the visible to the near-infrared. Since the fluorescent emission of Zn (II) and Cu (II) complexes are enhanced by the binding to nucleic acids upon visible light exposure when bound to DNA. These complexes are important as selective fluorescent probes for nucleic acids and to highlight their potential application. UV–vis spectroscopy is an accurate for finding the extent of ligand interaction with DNA and metallic complexes–DNA binding. Generally, the binding of intercalative compounds to DNA can be characterized through a
{"title":"Transition metal salphen DNA complexes as biosensor application for detecting various mosquito viruses","authors":"M. Monajjemi, Fatemeh Mollaamin","doi":"10.1108/sr-06-2022-0253","DOIUrl":"https://doi.org/10.1108/sr-06-2022-0253","url":null,"abstract":"\u0000Purpose\u0000Piperidine side chain-functionalized N, N′-bissalicylidene phenylene di amine di-anion (salphen) consisting of salphen-Zn and salphen-Cu are able to intercalate with nucleic base stacking of DNA and can be applied as an optical DNA hybridization detector. Attaching DNA and salphen to glass surfaces has been done via coating the surface with the silane coupling agents containing 3-aminopropyltriethoxysilane that was synthesized for acting as a high-affinity RNA carrier matrix. The Schiff base salphen-zinc (II) and salphen-Cu (II) complexes-labelled probe to target nucleic acid renders a colour change of the DNA biosensor to a green and red background colour for zinc and copper, respectively. This study aims to indicate that the DNA biosensor data with high efficiency is used for detection of dengue virus serotypes 2 (DENV-2) and Chikungunya virus (CHIKV) concentration via salphen-Zn (II) and salphen-Cu (II), respectively, in human samples.\u0000\u0000\u0000Design/methodology/approach\u00001H-NMR and 13C-NMR have been used via PerkinElmer LAMBDA 35 instrument. The authors also used a double beam spectrophotometer with (CH3)4Si (TMS) as reference and dimethyl sulfoxide as solvent reference in pH = 7.0. Various DNA concentrations have been used for UV spectrophotometry at 300 nm and 400 nm for zinc and copper complexes, respectively. BRUKER mass spectra with DIONEX Ultimate 3000 LC model were used for all measurements. Mettler Teledo model (DSC882e) of differential scanning calorimeter (DSC) was used for measure the melting temperature of metal zinc and copper complexes. The morphology of the silica Nano spheres (SiNs) were scanned by FESEM with Model JSM-6700F from Japan.\u0000\u0000\u0000Findings\u0000The Cu (II) and Zn (II)-salphen-viruses DNA system for CHIKV and DENV-2, respectively, in different concentration have been investigated via various spectroscopies (Figure 3). CHIKV and DENV-2 DNA were selected from human saliva and urine samples as models for conformations of human G4-DNA. By increasing the amounts of DNAs, and G4, the UV–Vis bands of located above 300 nm, experienced a hypochromic effect. The Cu2+ complex exhibits selectivity towards the G4, and there is a similar affinity for Zn2+ complex binds to the G4. These results collectively suggest that the Cu2+ complex is stronger than the Zn2+ complex. The authors have found copper (II) and zinc (II) compounds and nucleic acid-complexes are strongly fluorescent molecules in the low energy range, from the visible to the near-infrared. Since the fluorescent emission of Zn (II) and Cu (II) complexes are enhanced by the binding to nucleic acids upon visible light exposure when bound to DNA. These complexes are important as selective fluorescent probes for nucleic acids and to highlight their potential application. UV–vis spectroscopy is an accurate for finding the extent of ligand interaction with DNA and metallic complexes–DNA binding. Generally, the binding of intercalative compounds to DNA can be characterized through a","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":" ","pages":""},"PeriodicalIF":1.6,"publicationDate":"2023-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46666487","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}