首页 > 最新文献

Canadian Journal of Electrical and Computer Engineering-Revue Canadienne De Genie Electrique et Informatique最新文献

英文 中文
Guest Editorial: Special Issue on EPEC 2017 Éditorial invité: Numéro spécial sur EPEC 2017 特邀社论:EPEC 2017特刊特刊
IF 1.7 Q2 Engineering Pub Date : 2019-07-23 DOI: 10.1109/CJECE.2019.2898432
C. Chung, R. Karki, Raman Paranjape, S. Yousefi
Welcome to a Special Issue of the Canadian Journal of Electrical and Computer Engineering, which presents some of the top papers (in extended form) from the Electrical Power and Energy Conference (EPEC 2017) held in Saskatoon, SK, Canada, October 22–25, 2017. This conference was jointly organized by the IEEE North Saskatchewan Section and the IEEE South Saskatchewan Section, and this was the first time that it was held in Saskatoon.
欢迎来到加拿大电气与计算机工程杂志的特刊,其中介绍了2017年10月22日至25日在加拿大SK萨斯卡通举行的电力与能源会议(EPEC 2017)的一些顶级论文(扩展形式)。本次会议由IEEE北萨斯喀彻温分会和IEEE南萨斯喀彻温分会联合举办,首次在萨斯卡通举行。
{"title":"Guest Editorial: Special Issue on EPEC 2017 Éditorial invité: Numéro spécial sur EPEC 2017","authors":"C. Chung, R. Karki, Raman Paranjape, S. Yousefi","doi":"10.1109/CJECE.2019.2898432","DOIUrl":"https://doi.org/10.1109/CJECE.2019.2898432","url":null,"abstract":"Welcome to a Special Issue of the Canadian Journal of Electrical and Computer Engineering, which presents some of the top papers (in extended form) from the Electrical Power and Energy Conference (EPEC 2017) held in Saskatoon, SK, Canada, October 22–25, 2017. This conference was jointly organized by the IEEE North Saskatchewan Section and the IEEE South Saskatchewan Section, and this was the first time that it was held in Saskatoon.","PeriodicalId":55287,"journal":{"name":"Canadian Journal of Electrical and Computer Engineering-Revue Canadienne De Genie Electrique et Informatique","volume":"31 1","pages":"134-134"},"PeriodicalIF":1.7,"publicationDate":"2019-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86139685","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Novel MPPT Method Based on Cuckoo Search Algorithm and Golden Section Search Algorithm for Partially Shaded PV System 基于Cuckoo搜索算法和Golden Section搜索算法的部分阴影光伏系统MPPT新方法
IF 1.7 Q2 Engineering Pub Date : 2019-07-23 DOI: 10.1109/CJECE.2019.2914723
Dimas Aji Nugraha, K. Lian, .. Suwarno
Partial shading is a common and difficult problem to be solved in a photovoltaic (PV) system. Numerous efforts have been introduced to mitigate this problem. Some commonly used approaches are deploying some metaheuristic (MH) algorithm to track the multiple-peak $P - V$ curve of partially shaded PV system. Cuckoo search (CS) is a new optimization algorithm based on the MH approach. It has been used to solve an optimization problem in many applications, including the maximum power point tracking (MPPT) problem. The CS algorithm performs well in tracking the global maximum power point (GMPP). However, just like any other MH algorithm, there is still a dilemmatic trading between their accuracy and the tracking time needed to find GMPP. This paper proposes a new MPPT algorithm by combining the CS algorithm with golden section search (GSS) to take beneficial features from both the algorithms. To validate the proposed algorithm, it is evaluated with various cases of partial shading. The simulation and experimental results show a noticeable performance improvement compared with the original CS algorithm and other MH algorithms.
局部遮光是光伏系统中需要解决的一个常见而困难的问题。为缓解这一问题,已经作出了许多努力。一些常用的方法是部署一些元启发式(MH)算法来跟踪部分阴影光伏系统的多峰值$P-V$曲线。布谷鸟搜索(CS)是一种基于MH方法的新的优化算法。它已被用于解决许多应用中的优化问题,包括最大功率点跟踪(MPPT)问题。CS算法在跟踪全局最大功率点(GMPP)方面表现良好。然而,就像任何其他MH算法一样,它们的准确性和找到GMPP所需的跟踪时间之间仍然存在着艰难的交易。本文将CS算法与黄金分割搜索(GSS)相结合,提出了一种新的MPPT算法,以从这两种算法中提取有益的特征。为了验证所提出的算法,对不同的局部着色情况进行了评估。仿真和实验结果表明,与原来的CS算法和其他MH算法相比,性能有了显著的提高。
{"title":"A Novel MPPT Method Based on Cuckoo Search Algorithm and Golden Section Search Algorithm for Partially Shaded PV System","authors":"Dimas Aji Nugraha, K. Lian, .. Suwarno","doi":"10.1109/CJECE.2019.2914723","DOIUrl":"https://doi.org/10.1109/CJECE.2019.2914723","url":null,"abstract":"Partial shading is a common and difficult problem to be solved in a photovoltaic (PV) system. Numerous efforts have been introduced to mitigate this problem. Some commonly used approaches are deploying some metaheuristic (MH) algorithm to track the multiple-peak $P - V$ curve of partially shaded PV system. Cuckoo search (CS) is a new optimization algorithm based on the MH approach. It has been used to solve an optimization problem in many applications, including the maximum power point tracking (MPPT) problem. The CS algorithm performs well in tracking the global maximum power point (GMPP). However, just like any other MH algorithm, there is still a dilemmatic trading between their accuracy and the tracking time needed to find GMPP. This paper proposes a new MPPT algorithm by combining the CS algorithm with golden section search (GSS) to take beneficial features from both the algorithms. To validate the proposed algorithm, it is evaluated with various cases of partial shading. The simulation and experimental results show a noticeable performance improvement compared with the original CS algorithm and other MH algorithms.","PeriodicalId":55287,"journal":{"name":"Canadian Journal of Electrical and Computer Engineering-Revue Canadienne De Genie Electrique et Informatique","volume":"42 1","pages":"173-182"},"PeriodicalIF":1.7,"publicationDate":"2019-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/CJECE.2019.2914723","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44620810","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 57
Optimal Coordination of Double Primary Directional Overcurrent Relays Using a New Combinational BBO/DE Algorithm 基于BBO/DE组合算法的双初级方向过流继电器优化协调
IF 1.7 Q2 Engineering Pub Date : 2019-07-23 DOI: 10.1109/CJECE.2018.2802461
Ali R. Al-Roomi, M. El-Hawary
The optimal relay coordination (ORC) problem for directional overcurrent relays (DOCRs) has been solved by many conventional and modern optimization algorithms. All these studies were based on the common assumption that all DOCRs are numerical, digital “hardware-based,” static, or electromechanical. Unfortunately, the transition between these technologies does not happen instantaneously, so protection engineers could see different models of these protective relays in some real electric power systems. Moreover, when old electromechanical, static, and digital relays are replaced with the latest state-of-the-art numerical relays, the older relays are kept as backup protective devices. Some called them “primary” and “local-backup” relays, whereas others called them “main-1” and “main-2” relays. The reason behind the second terminology is the chance that the old relays could act ahead of the numerical relays. In this paper, a realistic mathematical model of the ORC problem is formulated and solved using a new hybrid evolutionary algorithm. To judge whether this realistic ORC problem is completely/partially solvable or not, the IEEE 6-bus, 15-bus, and 42-bus test systems are simulated. The results prove that the technique is an effective tool to indicate which relay sets accept/do not accept this double primary relay strategy.
定向过电流继电器(DOCR)的最优继电器协调(ORC)问题已经通过许多传统和现代的优化算法得到了解决。所有这些研究都基于一个共同的假设,即所有DOCR都是数字的、数字的“基于硬件的”、静态的或机电的。不幸的是,这些技术之间的转换并不是瞬间发生的,因此保护工程师可以在一些真实的电力系统中看到这些保护继电器的不同型号。此外,当旧的机电、静态和数字继电器被最新的最先进的数字继电器取代时,旧的继电器被保留为备用保护装置。一些人称它们为“主”和“本地备份”继电器,而另一些则称它们为“主要-1”和“主要-2”继电器。第二个术语背后的原因是旧继电器有可能先于数字继电器。本文建立了ORC问题的一个现实数学模型,并使用一种新的混合进化算法求解。为了判断这个现实的ORC问题是否完全/部分可解,对IEEE 6总线、15总线和42总线测试系统进行了仿真。结果证明,该技术是指示哪些继电器组接受/不接受这种双主继电器策略的有效工具。
{"title":"Optimal Coordination of Double Primary Directional Overcurrent Relays Using a New Combinational BBO/DE Algorithm","authors":"Ali R. Al-Roomi, M. El-Hawary","doi":"10.1109/CJECE.2018.2802461","DOIUrl":"https://doi.org/10.1109/CJECE.2018.2802461","url":null,"abstract":"The optimal relay coordination (ORC) problem for directional overcurrent relays (DOCRs) has been solved by many conventional and modern optimization algorithms. All these studies were based on the common assumption that all DOCRs are numerical, digital “hardware-based,” static, or electromechanical. Unfortunately, the transition between these technologies does not happen instantaneously, so protection engineers could see different models of these protective relays in some real electric power systems. Moreover, when old electromechanical, static, and digital relays are replaced with the latest state-of-the-art numerical relays, the older relays are kept as backup protective devices. Some called them “primary” and “local-backup” relays, whereas others called them “main-1” and “main-2” relays. The reason behind the second terminology is the chance that the old relays could act ahead of the numerical relays. In this paper, a realistic mathematical model of the ORC problem is formulated and solved using a new hybrid evolutionary algorithm. To judge whether this realistic ORC problem is completely/partially solvable or not, the IEEE 6-bus, 15-bus, and 42-bus test systems are simulated. The results prove that the technique is an effective tool to indicate which relay sets accept/do not accept this double primary relay strategy.","PeriodicalId":55287,"journal":{"name":"Canadian Journal of Electrical and Computer Engineering-Revue Canadienne De Genie Electrique et Informatique","volume":"42 1","pages":"135-147"},"PeriodicalIF":1.7,"publicationDate":"2019-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/CJECE.2018.2802461","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48594499","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 20
Measurement-Based Characteristic Curves for Voltage Stability and Control at the Point of Interconnection of Wind Power Plants 基于测量的风电场并网点电压稳定与控制特性曲线
IF 1.7 Q2 Engineering Pub Date : 2019-07-23 DOI: 10.1109/CJECE.2019.2906007
Xiaodong Liang, Md. Nasmus Sakib Khan Shabbir, N. Khan, Xiaodi Yan
In this paper, the measurement-based characteristic curves, reactive power–voltage ( $Q$ $V$ ) curve and reactive power–active power–voltage ( $Q$ $P$ $V$ ) curve, are developed for voltage stability and control at the point of interconnection (POI) between a wind power plant (WPP) and a utility grid. The procedure to obtain an effective $Q$ $V$ curve using the supervisory control and data acquisition (SCADA) measurement data is proposed. The SCADA data used in this paper were recorded in 2016 at the POI of a 27-MW WPP currently in operation in Newfoundland and Labrador (NL), Canada. Each $Q$ $V$ curve is created for a particular month using the SCADA data corresponding to a very narrowly defined active power range, so the active power is considered constant as the conventional $Q$ $V$ curve concept. The MATLAB curve fitting toolbox is used to realize the most fit mathematical equations for $Q$ $V$ and $Q$ $P$ $V$ curves. The developed $Q$ $V$ and $Q$ $P$ $V$ curves can be used for the data-driven voltage control for WPPs; and the $Q$ $V$ curves can also be used for the voltage stability evaluation.
本文提出了基于测量的特性曲线,即无功电压($Q$ - $V$)曲线和无功电压($Q$ - $P$ - $V$)曲线,用于风力发电厂与电网接入点的电压稳定与控制。提出了利用监控和数据采集(SCADA)测量数据获得有效的Q - V曲线的程序。本文中使用的SCADA数据是2016年在加拿大纽芬兰和拉布拉多(NL)运行的27兆瓦WPP的POI记录的。每个$Q$ - $V$曲线都是使用SCADA数据为特定月份创建的,对应于一个非常狭窄的有功功率范围,因此有功功率被认为是传统的$Q$ - $V$曲线概念。利用MATLAB曲线拟合工具箱实现$Q$ - $V$曲线和$Q$ - $P$ - $V$曲线的最拟合数学方程。所建立的$Q$ - $V$曲线和$Q$ - $P$ - $V$曲线可用于WPPs的数据驱动电压控制;Q ~ V曲线也可用于电压稳定性评价。
{"title":"Measurement-Based Characteristic Curves for Voltage Stability and Control at the Point of Interconnection of Wind Power Plants","authors":"Xiaodong Liang, Md. Nasmus Sakib Khan Shabbir, N. Khan, Xiaodi Yan","doi":"10.1109/CJECE.2019.2906007","DOIUrl":"https://doi.org/10.1109/CJECE.2019.2906007","url":null,"abstract":"In this paper, the measurement-based characteristic curves, reactive power–voltage (<inline-formula> <tex-math notation=\"LaTeX\">$Q$ </tex-math></inline-formula>–<inline-formula> <tex-math notation=\"LaTeX\">$V$ </tex-math></inline-formula>) curve and reactive power–active power–voltage (<inline-formula> <tex-math notation=\"LaTeX\">$Q$ </tex-math></inline-formula>–<inline-formula> <tex-math notation=\"LaTeX\">$P$ </tex-math></inline-formula>–<inline-formula> <tex-math notation=\"LaTeX\">$V$ </tex-math></inline-formula>) curve, are developed for voltage stability and control at the point of interconnection (POI) between a wind power plant (WPP) and a utility grid. The procedure to obtain an effective <inline-formula> <tex-math notation=\"LaTeX\">$Q$ </tex-math></inline-formula>–<inline-formula> <tex-math notation=\"LaTeX\">$V$ </tex-math></inline-formula> curve using the supervisory control and data acquisition (SCADA) measurement data is proposed. The SCADA data used in this paper were recorded in 2016 at the POI of a 27-MW WPP currently in operation in Newfoundland and Labrador (NL), Canada. Each <inline-formula> <tex-math notation=\"LaTeX\">$Q$ </tex-math></inline-formula>–<inline-formula> <tex-math notation=\"LaTeX\">$V$ </tex-math></inline-formula> curve is created for a particular month using the SCADA data corresponding to a very narrowly defined active power range, so the active power is considered constant as the conventional <inline-formula> <tex-math notation=\"LaTeX\">$Q$ </tex-math></inline-formula>–<inline-formula> <tex-math notation=\"LaTeX\">$V$ </tex-math></inline-formula> curve concept. The MATLAB curve fitting toolbox is used to realize the most fit mathematical equations for <inline-formula> <tex-math notation=\"LaTeX\">$Q$ </tex-math></inline-formula>–<inline-formula> <tex-math notation=\"LaTeX\">$V$ </tex-math></inline-formula> and <inline-formula> <tex-math notation=\"LaTeX\">$Q$ </tex-math></inline-formula>–<inline-formula> <tex-math notation=\"LaTeX\">$P$ </tex-math></inline-formula>–<inline-formula> <tex-math notation=\"LaTeX\">$V$ </tex-math></inline-formula> curves. The developed <inline-formula> <tex-math notation=\"LaTeX\">$Q$ </tex-math></inline-formula>–<inline-formula> <tex-math notation=\"LaTeX\">$V$ </tex-math></inline-formula> and <inline-formula> <tex-math notation=\"LaTeX\">$Q$ </tex-math></inline-formula>–<inline-formula> <tex-math notation=\"LaTeX\">$P$ </tex-math></inline-formula>–<inline-formula> <tex-math notation=\"LaTeX\">$V$ </tex-math></inline-formula> curves can be used for the data-driven voltage control for WPPs; and the <inline-formula> <tex-math notation=\"LaTeX\">$Q$ </tex-math></inline-formula>–<inline-formula> <tex-math notation=\"LaTeX\">$V$ </tex-math></inline-formula> curves can also be used for the voltage stability evaluation.","PeriodicalId":55287,"journal":{"name":"Canadian Journal of Electrical and Computer Engineering-Revue Canadienne De Genie Electrique et Informatique","volume":"42 1","pages":"163-172"},"PeriodicalIF":1.7,"publicationDate":"2019-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/CJECE.2019.2906007","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44565618","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Transformation Method of Nonlinear Mathematical Models of the DC Series Drive into the Form of Modified Recurrent Neural Network 直流串联传动非线性数学模型转化为修正递归神经网络的方法
IF 1.7 Q2 Engineering Pub Date : 2019-06-24 DOI: 10.1109/CJECE.2018.2885855
I. Orlovskyi
The method of transformation of a nonlinear mathematical model of an electromechanical object to the form of a modified artificial recurrent neural network has been further developed. The method makes it possible to use knowledge about the object for the synthesis of a recurrent neural network (RNN) structure and the computation of their coefficients. Nonlinearities in the proposed RNN were realized by expanding the input signal space of the network, using the normalized signals of polynomial terms. Mathematical transformations were performed for a model of thyristor-based electric drive with a dc motor of series excitation. In the electric drive model, different nonlinearities were set, namely, the magnetic flux and inductance of the motor winding dependence on the motor current and its derivative, the thyristor converter gain from the reference voltage, and the dependence of the moment of inertia on the speed. An accuracy estimation for the models in the form of an RNN was made.
进一步发展了将机电对象的非线性数学模型转换为改进的人工递归神经网络形式的方法。该方法使得可以使用关于对象的知识来合成递归神经网络(RNN)结构及其系数的计算。所提出的RNN中的非线性是通过使用多项式项的归一化信号来扩展网络的输入信号空间来实现的。对串联励磁直流电机的晶闸管电驱动模型进行了数学变换。在电驱动模型中,设置了不同的非线性,即电机绕组的磁通量和电感依赖于电机电流及其导数,晶闸管转换器从参考电压获得的增益,以及惯性矩依赖于速度。以RNN的形式对模型进行了精度估计。
{"title":"Transformation Method of Nonlinear Mathematical Models of the DC Series Drive into the Form of Modified Recurrent Neural Network","authors":"I. Orlovskyi","doi":"10.1109/CJECE.2018.2885855","DOIUrl":"https://doi.org/10.1109/CJECE.2018.2885855","url":null,"abstract":"The method of transformation of a nonlinear mathematical model of an electromechanical object to the form of a modified artificial recurrent neural network has been further developed. The method makes it possible to use knowledge about the object for the synthesis of a recurrent neural network (RNN) structure and the computation of their coefficients. Nonlinearities in the proposed RNN were realized by expanding the input signal space of the network, using the normalized signals of polynomial terms. Mathematical transformations were performed for a model of thyristor-based electric drive with a dc motor of series excitation. In the electric drive model, different nonlinearities were set, namely, the magnetic flux and inductance of the motor winding dependence on the motor current and its derivative, the thyristor converter gain from the reference voltage, and the dependence of the moment of inertia on the speed. An accuracy estimation for the models in the form of an RNN was made.","PeriodicalId":55287,"journal":{"name":"Canadian Journal of Electrical and Computer Engineering-Revue Canadienne De Genie Electrique et Informatique","volume":"42 1","pages":"68-77"},"PeriodicalIF":1.7,"publicationDate":"2019-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/CJECE.2018.2885855","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45666015","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Toward a Way to Benchmark Multilevel Inverter Topologies Based on Level to Components Ratio 基于电平与元件比的多电平逆变器拓扑基准测试方法研究
IF 1.7 Q2 Engineering Pub Date : 2019-06-24 DOI: 10.1109/CJECE.2019.2892087
A. Sheir, M. Orabi, M. Youssef, Mahrous E. Ahmed
This paper introduces a generalized platform for the design selection of multilevel inverters (MLIs) topologies for any industry, especially in low- and medium-power applications. This platform is novel as it combines the component count and stress in any MLI in a normalized unique score. Each MLI topology is designed to match specific criteria to meet a specific application, which introduces diversified sets of merits and demerits in each case. Therefore, choosing a suitable MLI topology for the specific application is rather a difficult, time-consuming, and complex process. Moreover, the comparison can only be conducted between MLI topologies that fall under the same category. This paper introduces a comprehensive study to propose a new benchmark (BM) which can be used to compare MLI topologies regardless of their constructions or oriented applications. Each MLI topology gets a BM score based on comparative factors that evaluate its components quantitatively and qualitatively. Thus, comparing different types of MLI topologies is a simple process of comparing their calculated BM scores leading to better well-informed choice. First, the proposed BM-derived forms are discussed. Then, the proposed methodology is illustrated by applying to various types of MLI topologies including conventional and recently introduced ones.
本文介绍了一个适用于任何行业,特别是中、低功率应用的多电平逆变器(mli)拓扑设计选择的通用平台。该平台是新颖的,因为它将任何MLI中的组件计数和应力结合在一个标准化的唯一分数中。每个MLI拓扑都设计为满足特定应用的特定标准,这在每种情况下引入了不同的优点和缺点集。因此,为特定的应用程序选择合适的MLI拓扑是一个相当困难、耗时和复杂的过程。而且,只能在属于同一类别的MLI拓扑之间进行比较。本文介绍了一项全面的研究,提出了一个新的基准(BM),可以用来比较不同结构或面向应用的MLI拓扑。每个MLI拓扑根据定量和定性地评估其组成部分的比较因素获得一个BM分数。因此,比较不同类型的MLI拓扑是一个简单的过程,比较它们计算的BM分数,从而更好地做出明智的选择。首先,讨论了所提出的bm派生形式。然后,通过应用各种类型的MLI拓扑(包括传统拓扑和最近引入的拓扑)来说明所提出的方法。
{"title":"Toward a Way to Benchmark Multilevel Inverter Topologies Based on Level to Components Ratio","authors":"A. Sheir, M. Orabi, M. Youssef, Mahrous E. Ahmed","doi":"10.1109/CJECE.2019.2892087","DOIUrl":"https://doi.org/10.1109/CJECE.2019.2892087","url":null,"abstract":"This paper introduces a generalized platform for the design selection of multilevel inverters (MLIs) topologies for any industry, especially in low- and medium-power applications. This platform is novel as it combines the component count and stress in any MLI in a normalized unique score. Each MLI topology is designed to match specific criteria to meet a specific application, which introduces diversified sets of merits and demerits in each case. Therefore, choosing a suitable MLI topology for the specific application is rather a difficult, time-consuming, and complex process. Moreover, the comparison can only be conducted between MLI topologies that fall under the same category. This paper introduces a comprehensive study to propose a new benchmark (BM) which can be used to compare MLI topologies regardless of their constructions or oriented applications. Each MLI topology gets a BM score based on comparative factors that evaluate its components quantitatively and qualitatively. Thus, comparing different types of MLI topologies is a simple process of comparing their calculated BM scores leading to better well-informed choice. First, the proposed BM-derived forms are discussed. Then, the proposed methodology is illustrated by applying to various types of MLI topologies including conventional and recently introduced ones.","PeriodicalId":55287,"journal":{"name":"Canadian Journal of Electrical and Computer Engineering-Revue Canadienne De Genie Electrique et Informatique","volume":"42 1","pages":"78-92"},"PeriodicalIF":1.7,"publicationDate":"2019-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/CJECE.2019.2892087","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43628904","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Dynamic Phasor Modeling of LCC-HVDC Systems: Unbalanced Operation and Commutation Failure LCC-HVDC系统的动态相量建模:不平衡运行和换流故障
IF 1.7 Q2 Engineering Pub Date : 2019-06-24 DOI: 10.1109/CJECE.2019.2903842
M. Daryabak, S. Filizadeh, Afshin Bagheri Vandaei
This paper develops a dynamic phasor model of a line-commutated converter high-voltage direct current (LCC-HVDC) system that includes unbalanced operation and commutation failure. This model is beneficial in studying the behavior of the HVDC systems under asymmetrical faults, and it complements the conventional transient simulation-based methods. Equally, importantly, the model includes the representation of commutation failure that may arise as a result of severe faults. Due to its selectivity of the considered harmonics, the developed model has markedly less computational intensity than an electromagnetic transient (EMT) simulation model. This gives the model a distinct advantage in the study of large-signal transients of the LCC-HVDC systems, particularly where repetitive simulations are required. Validation of the proposed model is done using a detailed EMT model of the CIGRE monopolar LCC-HVDC benchmark.
本文建立了包括不平衡运行和换相故障的线路换流器高压直流系统的动态相量模型。该模型有利于研究HVDC系统在不对称故障下的行为,并补充了传统的基于暂态仿真的方法。同样重要的是,该模型包括严重故障可能导致的换向故障的表示。由于其对所考虑谐波的选择性,所开发的模型的计算强度明显低于电磁暂态(EMT)模拟模型。这使该模型在LCC-HVDC系统的大信号瞬态研究中具有明显的优势,特别是在需要重复模拟的情况下。使用CIGRE单极LCC-HVDC基准的详细EMT模型对所提出的模型进行了验证。
{"title":"Dynamic Phasor Modeling of LCC-HVDC Systems: Unbalanced Operation and Commutation Failure","authors":"M. Daryabak, S. Filizadeh, Afshin Bagheri Vandaei","doi":"10.1109/CJECE.2019.2903842","DOIUrl":"https://doi.org/10.1109/CJECE.2019.2903842","url":null,"abstract":"This paper develops a dynamic phasor model of a line-commutated converter high-voltage direct current (LCC-HVDC) system that includes unbalanced operation and commutation failure. This model is beneficial in studying the behavior of the HVDC systems under asymmetrical faults, and it complements the conventional transient simulation-based methods. Equally, importantly, the model includes the representation of commutation failure that may arise as a result of severe faults. Due to its selectivity of the considered harmonics, the developed model has markedly less computational intensity than an electromagnetic transient (EMT) simulation model. This gives the model a distinct advantage in the study of large-signal transients of the LCC-HVDC systems, particularly where repetitive simulations are required. Validation of the proposed model is done using a detailed EMT model of the CIGRE monopolar LCC-HVDC benchmark.","PeriodicalId":55287,"journal":{"name":"Canadian Journal of Electrical and Computer Engineering-Revue Canadienne De Genie Electrique et Informatique","volume":"42 1","pages":"121-131"},"PeriodicalIF":1.7,"publicationDate":"2019-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/CJECE.2019.2903842","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48036687","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Low-Power Highly Reliable SET-Induced Dual-Node Upset-Hardened Latch and Flip-Flop 低功耗高可靠性SET诱导的双节点翻转硬化锁存器和触发器
IF 1.7 Q2 Engineering Pub Date : 2019-06-24 DOI: 10.1109/CJECE.2019.2895047
Riadul Islam
It appears that the relentless pursuit of Moore’s law scaling from one generation of process technology to the next increases circuit vulnerability to single-event transient (SET)-induced double-node upset (SEDU). In this paper, we present a novel SEDU-hardened latch. The latch consists of a new 16-transistor (16T) SEDU-hardened storage cell and a C-type output buffer. The latch exhibits 25% lower power consumption, is 81% faster, and also shows 86% lower power-delay product than the existing SEDU-hardened latches. In addition, we present the first SEDU-hardened flip-flop that exhibits negative hold time. The proposed SEDU-hardened flip-flop is 29% faster, consumes 50% lower dynamic power and 25% lower static power, has 45% lower setup time, and uses 27% lower area than the existing partial SEDU-hardened flip-flop.
从一代工艺技术到下一代工艺工艺技术,对摩尔定律的不懈追求似乎增加了电路对单事件瞬态(SET)引起的双节点扰乱(SEDU)的脆弱性。在本文中,我们提出了一种新型的SEDU硬化闩锁。锁存器由一个新的16晶体管(16T)SEDU硬化存储单元和一个C型输出缓冲器组成。与现有的SEDU硬化锁存器相比,该锁存器的功耗降低了25%,速度加快了81%,并且功率延迟乘积也降低了86%。此外,我们还提出了第一个具有负保持时间的SEDU硬化触发器。所提出的SEDU硬化触发器比现有的部分SEDU硬化的触发器快29%,消耗50%的动态功率和25%的静态功率,具有45%的设置时间,并且使用27%的面积。
{"title":"Low-Power Highly Reliable SET-Induced Dual-Node Upset-Hardened Latch and Flip-Flop","authors":"Riadul Islam","doi":"10.1109/CJECE.2019.2895047","DOIUrl":"https://doi.org/10.1109/CJECE.2019.2895047","url":null,"abstract":"It appears that the relentless pursuit of Moore’s law scaling from one generation of process technology to the next increases circuit vulnerability to single-event transient (SET)-induced double-node upset (SEDU). In this paper, we present a novel SEDU-hardened latch. The latch consists of a new 16-transistor (16T) SEDU-hardened storage cell and a C-type output buffer. The latch exhibits 25% lower power consumption, is 81% faster, and also shows 86% lower power-delay product than the existing SEDU-hardened latches. In addition, we present the first SEDU-hardened flip-flop that exhibits negative hold time. The proposed SEDU-hardened flip-flop is 29% faster, consumes 50% lower dynamic power and 25% lower static power, has 45% lower setup time, and uses 27% lower area than the existing partial SEDU-hardened flip-flop.","PeriodicalId":55287,"journal":{"name":"Canadian Journal of Electrical and Computer Engineering-Revue Canadienne De Genie Electrique et Informatique","volume":"42 1","pages":"93-101"},"PeriodicalIF":1.7,"publicationDate":"2019-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/CJECE.2019.2895047","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45236818","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Discretization of the Firefly Algorithm for Home Care 居家护理萤火虫算法的离散化
IF 1.7 Q2 Engineering Pub Date : 2019-04-02 DOI: 10.1109/CJECE.2018.2883030
L. Dekhici, R. Redjem, K. Belkadi, A. E. Mhamedi
This paper aims to solve the problem of home-care routing by using a metaheuristic inspired by nature which is the firefly (FF) algorithm. A good discretization and correction of the solution was provided to maintain the advantages of such an algorithm on this combinatorial problem. Even if the problem is only an extension of the vehicle routing problem with time windows (TWVRP), the human aspect hardens it so that any abuse of a constraint can destroy the feasibility or reduce the services quality. Hard constraints concern the precedence between cares and a patient cares synchronization, while soft constraints concern time windows preferences. The problem in this paper also takes into account overtime and the painfulness of home workers. The main purpose is to minimize the routing total duration and to maximize the constraints satisfaction. The results on two examples show that the discrete version of the FF algorithm gives a better total travel time and better satisfies the constraints.
本文旨在利用自然界启发的元启发式算法——萤火虫算法(FF)来解决居家护理路径问题。为了保持该算法在组合问题上的优势,对解进行了良好的离散化和校正。即使该问题只是带时间窗车辆路径问题的扩展,人为因素也会使其变得更加复杂,任何约束的滥用都可能破坏可行性或降低服务质量。硬约束涉及护理和患者护理同步之间的优先级,而软约束涉及时间窗口偏好。本文的问题还考虑了加班和家庭工作者的痛苦。其主要目的是最小化路由总时间和最大化约束满足。两个算例的结果表明,离散版本的FF算法得到了更好的总行程时间,并且更好地满足了约束条件。
{"title":"Discretization of the Firefly Algorithm for Home Care","authors":"L. Dekhici, R. Redjem, K. Belkadi, A. E. Mhamedi","doi":"10.1109/CJECE.2018.2883030","DOIUrl":"https://doi.org/10.1109/CJECE.2018.2883030","url":null,"abstract":"This paper aims to solve the problem of home-care routing by using a metaheuristic inspired by nature which is the firefly (FF) algorithm. A good discretization and correction of the solution was provided to maintain the advantages of such an algorithm on this combinatorial problem. Even if the problem is only an extension of the vehicle routing problem with time windows (TWVRP), the human aspect hardens it so that any abuse of a constraint can destroy the feasibility or reduce the services quality. Hard constraints concern the precedence between cares and a patient cares synchronization, while soft constraints concern time windows preferences. The problem in this paper also takes into account overtime and the painfulness of home workers. The main purpose is to minimize the routing total duration and to maximize the constraints satisfaction. The results on two examples show that the discrete version of the FF algorithm gives a better total travel time and better satisfies the constraints.","PeriodicalId":55287,"journal":{"name":"Canadian Journal of Electrical and Computer Engineering-Revue Canadienne De Genie Electrique et Informatique","volume":"42 1","pages":"20-26"},"PeriodicalIF":1.7,"publicationDate":"2019-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/CJECE.2018.2883030","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45388578","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Analysis of Bootstrap Circuit Operation With an Inverted PWM Drive Scheme for a Three-Phase Inverter for a Brushless DC Motor Drive 无刷直流电机驱动用三相逆变器的反相PWM驱动方案的自举电路运行分析
IF 1.7 Q2 Engineering Pub Date : 2019-04-02 DOI: 10.1109/CJECE.2019.2891850
Yongkeun Lee, Jongkwan Kim
A bootstrap circuit for operating the high-side insulated-gate bipolar transistor of a three-phase inverter for a brushless dc motor drive is analyzed theoretically to avoid under voltage lockout by minimizing the discharge of a bootstrap capacitor (BSC). Unlike various methods of reducing the discharge of BSCs, which limits the controllability of the motor speed/torque, a proposed inverted PWM driving scheme has no limit to the controllability while maintaining the proper voltage level for a BSC. This method is verified experimentally in this paper.
从理论上分析了一种用于操作无刷直流电机驱动的三相逆变器的高侧绝缘栅双极晶体管的自举电路,以通过最小化自举电容器(BSC)的放电来避免欠压锁定。与限制电动机速度/转矩的可控性的减少BSC放电的各种方法不同,所提出的反向PWM驱动方案在保持BSC的适当电压电平的同时对可控性没有限制。本文对该方法进行了实验验证。
{"title":"Analysis of Bootstrap Circuit Operation With an Inverted PWM Drive Scheme for a Three-Phase Inverter for a Brushless DC Motor Drive","authors":"Yongkeun Lee, Jongkwan Kim","doi":"10.1109/CJECE.2019.2891850","DOIUrl":"https://doi.org/10.1109/CJECE.2019.2891850","url":null,"abstract":"A bootstrap circuit for operating the high-side insulated-gate bipolar transistor of a three-phase inverter for a brushless dc motor drive is analyzed theoretically to avoid under voltage lockout by minimizing the discharge of a bootstrap capacitor (BSC). Unlike various methods of reducing the discharge of BSCs, which limits the controllability of the motor speed/torque, a proposed inverted PWM driving scheme has no limit to the controllability while maintaining the proper voltage level for a BSC. This method is verified experimentally in this paper.","PeriodicalId":55287,"journal":{"name":"Canadian Journal of Electrical and Computer Engineering-Revue Canadienne De Genie Electrique et Informatique","volume":"42 1","pages":"58-65"},"PeriodicalIF":1.7,"publicationDate":"2019-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/CJECE.2019.2891850","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42501917","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
期刊
Canadian Journal of Electrical and Computer Engineering-Revue Canadienne De Genie Electrique et Informatique
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1