Novel Monolithic Silicon Probes with Flexible Parylene Cables for Neural Prostheses 神经假体用柔性聚对二甲苯电缆新型单片硅探针
Pub Date : 2006-05-09 DOI: 10.1109/MMB.2006.251491
C. Pang, S. Musallam, Y. Tai, J. Burdick, R. Andersen
This work presents the first parylene-insulated silicon probes, which are used for neural prostheses to record high-level cognitive neural signals. With parylene technology, our probes have several advantages compared with the current devices. First, instead of inorganic materials (e.g. SiO2 and Si3N4), the electrodes and conduction traces on the probes are insulated by parylene, an easily-deposited polymer with mechanical flexibility and biocompatibility. As a result, the probes exhibit better electrical and mechanical properties. Second, flexible parylene cables are monolithically integrated with the probes, which arm the probes with very high flexibility to be easily assembled to a high density 3-D array and at the same time provide an ideal method to transmit neural signals through skull during chronic recording. The all dry fabrication process and an 8times2 probe array (64 electrodes) were demonstrated. The probes were successfully tested electrically and mechanically in rat and monkey cortex. Neural signals were properly recorded
这项工作提出了第一个聚苯乙烯绝缘硅探针,用于神经假体来记录高水平的认知神经信号。利用聚对二甲苯技术,我们的探针与现有的设备相比具有许多优点。首先,代替无机材料(如SiO2和Si3N4),电极和探针上的传导痕迹由聚对二甲苯绝缘,聚对二甲苯是一种易于沉积的聚合物,具有机械灵活性和生物相容性。因此,探针表现出更好的电气和机械性能。其次,柔性的聚对二甲苯电缆与探头集成在一起,这使得探头具有很高的灵活性,可以很容易地组装成高密度的3-D阵列,同时提供了一种在慢性记录过程中通过颅骨传输神经信号的理想方法。演示了全干制工艺和8times2探针阵列(64个电极)。这些探针在大鼠和猴子的皮层中成功地进行了电和机械测试。神经信号被正确记录
{"title":"Novel Monolithic Silicon Probes with Flexible Parylene Cables for Neural Prostheses","authors":"C. Pang, S. Musallam, Y. Tai, J. Burdick, R. Andersen","doi":"10.1109/MMB.2006.251491","DOIUrl":"https://doi.org/10.1109/MMB.2006.251491","url":null,"abstract":"This work presents the first parylene-insulated silicon probes, which are used for neural prostheses to record high-level cognitive neural signals. With parylene technology, our probes have several advantages compared with the current devices. First, instead of inorganic materials (e.g. SiO2 and Si3N4), the electrodes and conduction traces on the probes are insulated by parylene, an easily-deposited polymer with mechanical flexibility and biocompatibility. As a result, the probes exhibit better electrical and mechanical properties. Second, flexible parylene cables are monolithically integrated with the probes, which arm the probes with very high flexibility to be easily assembled to a high density 3-D array and at the same time provide an ideal method to transmit neural signals through skull during chronic recording. The all dry fabrication process and an 8times2 probe array (64 electrodes) were demonstrated. The probes were successfully tested electrically and mechanically in rat and monkey cortex. Neural signals were properly recorded","PeriodicalId":170356,"journal":{"name":"2006 International Conference on Microtechnologies in Medicine and Biology","volume":"62 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115756899","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
Design and Fabrication of Vertical Electrodes in Microchannels for Particles/cells Sorting by Dielectrophoresis 介质电泳颗粒/细胞分选微通道垂直电极的设计与制备
Pub Date : 2006-05-09 DOI: 10.1109/MMB.2006.251513
L. Wang, S. Marchenko, J. Huang, N. Jeon, E. Monuki, L. Flanagan, A.P. Lee
We have developed a process to fabricate vertical electrodes in the side walls of the microchannel. With appropriate electrodes design, DEP force along the lateral direction of the channel can be generated so that one can position participates along the width dimension of the channel. The effect of different electrode configurations on the efficacy of generating non-uniform electric field distribution has been studied by FEM simulation with CFD-ACE. Electrodes with various length ratios and interdigited electrodes have been designed and studied on the generation of non-uniformity of the electric field. Compared to electrodes with different length ratios, side-wall interdigited electrodes provide more consistent direction of DEP force. Experiments on the manipulation of polystyrene microbeads and HEK293 cells with DEP have been demonstrated to verify the performance of the design. The particles/cells can be focused in the middle of the channel, trapped on the side walls, and sorted to different outlets by the flow
我们已经开发了一种在微通道侧壁制造垂直电极的工艺。通过适当的电极设计,可以沿通道的横向方向产生DEP力,从而可以沿通道的宽度尺寸定位参与者。采用CFD-ACE软件进行有限元模拟,研究了不同电极配置对产生非均匀电场分布效果的影响。设计并研究了不同长度比电极和交叉电极对电场不均匀性的产生。与不同长度比的电极相比,侧壁交错电极提供更一致的DEP力方向。用DEP处理聚苯乙烯微珠和HEK293细胞的实验验证了该设计的性能。颗粒/细胞可以集中在通道的中间,被困在侧壁上,并被水流分选到不同的出口
{"title":"Design and Fabrication of Vertical Electrodes in Microchannels for Particles/cells Sorting by Dielectrophoresis","authors":"L. Wang, S. Marchenko, J. Huang, N. Jeon, E. Monuki, L. Flanagan, A.P. Lee","doi":"10.1109/MMB.2006.251513","DOIUrl":"https://doi.org/10.1109/MMB.2006.251513","url":null,"abstract":"We have developed a process to fabricate vertical electrodes in the side walls of the microchannel. With appropriate electrodes design, DEP force along the lateral direction of the channel can be generated so that one can position participates along the width dimension of the channel. The effect of different electrode configurations on the efficacy of generating non-uniform electric field distribution has been studied by FEM simulation with CFD-ACE. Electrodes with various length ratios and interdigited electrodes have been designed and studied on the generation of non-uniformity of the electric field. Compared to electrodes with different length ratios, side-wall interdigited electrodes provide more consistent direction of DEP force. Experiments on the manipulation of polystyrene microbeads and HEK293 cells with DEP have been demonstrated to verify the performance of the design. The particles/cells can be focused in the middle of the channel, trapped on the side walls, and sorted to different outlets by the flow","PeriodicalId":170356,"journal":{"name":"2006 International Conference on Microtechnologies in Medicine and Biology","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125555557","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Evaluation of Lamination Micro Mixer for Micro Immunomagnetic Cell Sorter 微免疫磁性细胞分选机层压微混合器的评价
Pub Date : 2006-05-09 DOI: 10.1109/MMB.2006.251509
H. Inokuchi, K. Nagae, Y. Suzuki, N. Kasagi, N. Shikazono
A split-and-recombine lamination mixer for mu-immunomagnetic cell sorting system has been developed for extracting stem cells from peripheral blood. Cell suspension is mixed with antibody-coated magnetic beads, and target cells are labeled with antigen-antibody reaction. In this report, the mixer performance is evaluated quantitatively by using human umbilical vein endothelial cells (HUVEC). The number of magnetic beads attached to the target cell is evaluated in two different arrangements of the mixer units
研制了一种用于多免疫细胞分选系统的分裂-重组层压混合器,用于提取外周血干细胞。将细胞悬液与抗体包被的磁珠混合,用抗原-抗体反应标记靶细胞。在本报告中,使用人脐静脉内皮细胞(HUVEC)定量评估混合器的性能。在混合单元的两种不同布置中评估附着在目标单元上的磁珠的数量
{"title":"Evaluation of Lamination Micro Mixer for Micro Immunomagnetic Cell Sorter","authors":"H. Inokuchi, K. Nagae, Y. Suzuki, N. Kasagi, N. Shikazono","doi":"10.1109/MMB.2006.251509","DOIUrl":"https://doi.org/10.1109/MMB.2006.251509","url":null,"abstract":"A split-and-recombine lamination mixer for mu-immunomagnetic cell sorting system has been developed for extracting stem cells from peripheral blood. Cell suspension is mixed with antibody-coated magnetic beads, and target cells are labeled with antigen-antibody reaction. In this report, the mixer performance is evaluated quantitatively by using human umbilical vein endothelial cells (HUVEC). The number of magnetic beads attached to the target cell is evaluated in two different arrangements of the mixer units","PeriodicalId":170356,"journal":{"name":"2006 International Conference on Microtechnologies in Medicine and Biology","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125768586","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Dielectrophoresis, cell culture, and Electrical Impedance Spectroscopy Applied to Adherent Cells in a Single Biochip 介质电泳,细胞培养和电阻抗谱应用于贴壁细胞在一个单一的生物芯片
Pub Date : 2006-05-09 DOI: 10.1109/MMB.2006.251518
E. Lennon, S. Ostrovidov, V. Senez, T. Fujii
In this work, we present a device that performs the 4 following functions: fluidic handling of biological cells suspension, electrical manipulation of cells by dielectrophoresis, cell culture and electrical impedance detection of adherent cells. Microfabrication process of the device, a hybrid glass/metal/PDMS structure, is detailed. Dielectrophoretic manipulation, culture and cell detection have been performed in a single device using human hepatocellular liver carcinoma cell. Results of broadband (10-107 Hz) electrical impedance spectroscopy (EIS) measurement performed on human cancerous cells are exposed
在这项工作中,我们提出了一种具有以下4种功能的装置:生物细胞悬浮液的流体处理,通过电泳法对细胞进行电操作,细胞培养和贴壁细胞的电阻抗检测。详细介绍了玻璃/金属/PDMS混合结构器件的微加工工艺。介电泳操作,培养和细胞检测已完成在一个单一的装置使用人肝细胞肝癌细胞。揭示了宽带(10-107 Hz)电阻抗谱(EIS)测量人类癌细胞的结果
{"title":"Dielectrophoresis, cell culture, and Electrical Impedance Spectroscopy Applied to Adherent Cells in a Single Biochip","authors":"E. Lennon, S. Ostrovidov, V. Senez, T. Fujii","doi":"10.1109/MMB.2006.251518","DOIUrl":"https://doi.org/10.1109/MMB.2006.251518","url":null,"abstract":"In this work, we present a device that performs the 4 following functions: fluidic handling of biological cells suspension, electrical manipulation of cells by dielectrophoresis, cell culture and electrical impedance detection of adherent cells. Microfabrication process of the device, a hybrid glass/metal/PDMS structure, is detailed. Dielectrophoretic manipulation, culture and cell detection have been performed in a single device using human hepatocellular liver carcinoma cell. Results of broadband (10-107 Hz) electrical impedance spectroscopy (EIS) measurement performed on human cancerous cells are exposed","PeriodicalId":170356,"journal":{"name":"2006 International Conference on Microtechnologies in Medicine and Biology","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125955137","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Microfluidic Immunoassay for Alveolar Cell Released Interleukin-8 Using a Braille Display for Computer-Controlled Fluid Actuation 微流体免疫分析肺泡细胞释放白介素-8使用盲文显示计算机控制的流体驱动
Pub Date : 2006-05-09 DOI: 10.1109/MMB.2006.251487
Y. Kamotani, W. Gu, N. Futai, S. Takayama
We have developed a self-contained, connectorless, automated microfluidic immunoassay system to detect and quantify levels of Interleukin (IL)-8, an important cytokine involved in the inflammatory response. In our microfluidic system, liquid flow is controlled using the pins of a commercially available, refreshable Braille display that act as small mechanical actuators. The successful development of such a microsystem will prove beneficial in both the early diagnosis and treatment of various disease states. Integration of the microfluidic immunoassay system with cell culture can provide a novel, self-contained device to analyze the by-products of chemically stimulated cells in a controlled microenvironment
我们开发了一种独立的、无连接的、自动化的微流控免疫分析系统,用于检测和量化白细胞介素(IL)-8的水平,IL -8是一种参与炎症反应的重要细胞因子。在我们的微流体系统中,液体流动是使用市售的、可刷新的盲文显示器的引脚来控制的,该显示器充当小型机械执行器。这种微系统的成功开发将有助于各种疾病状态的早期诊断和治疗。将微流控免疫分析系统与细胞培养相结合,可以提供一种新的、独立的设备来分析受控微环境中化学刺激细胞的副产物
{"title":"Microfluidic Immunoassay for Alveolar Cell Released Interleukin-8 Using a Braille Display for Computer-Controlled Fluid Actuation","authors":"Y. Kamotani, W. Gu, N. Futai, S. Takayama","doi":"10.1109/MMB.2006.251487","DOIUrl":"https://doi.org/10.1109/MMB.2006.251487","url":null,"abstract":"We have developed a self-contained, connectorless, automated microfluidic immunoassay system to detect and quantify levels of Interleukin (IL)-8, an important cytokine involved in the inflammatory response. In our microfluidic system, liquid flow is controlled using the pins of a commercially available, refreshable Braille display that act as small mechanical actuators. The successful development of such a microsystem will prove beneficial in both the early diagnosis and treatment of various disease states. Integration of the microfluidic immunoassay system with cell culture can provide a novel, self-contained device to analyze the by-products of chemically stimulated cells in a controlled microenvironment","PeriodicalId":170356,"journal":{"name":"2006 International Conference on Microtechnologies in Medicine and Biology","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122197504","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Implantable Unpowered Parylene MEMS Intraocular Pressure Sensor 植入式无动力聚对二甲苯MEMS眼压传感器
Pub Date : 2006-05-09 DOI: 10.1109/MMB.2006.251543
P.-J. Chen, D. Rodger, E. Meng, M. Humayun, Y. Tai
This paper presents the first implantable, unpowered, parylene-based micro-electro-mechanical-systems (MEMS) pressure sensor for intraocular pressure (IOP) sensing. From in situ mechanical deformation of the compliant structures, this sensor registers pressure variations without power consumption/transduction. Micromachined high-aspect-ratio thin-walled tubes in different geometric layouts are exploited to obtain a high-sensitivity pressure response. An integrated packaging method has been successfully developed to realize suture-less implantation of the device. In vitro testing results have demonstrated that the IOP sensor can achieve 0.67 degree/mmHg angular sensitivity with a spiral-tube design, 3.43 mum/mmHg lateral sensitivity with a long-armed-tube design, and 0.38 mum/mmHg longitudinal sensitivity with a serpentine-tube design. This IOP sensor is designed to be implanted in the anterior chamber of the eye and anchored directly on the iris so that, under incident visible light, the pressure response of the implant can be directly observed from outside the eye, which enables faithful and unpowered IOP monitoring in glaucoma patients
本文介绍了第一个可植入的、无动力的、基于聚苯乙烯的微机电系统(MEMS)眼压传感器。从柔性结构的原位机械变形,该传感器记录压力变化,而无需功耗/转导。利用不同几何布局的微机械高纵横比薄壁管来获得高灵敏度的压力响应。成功开发了一种集成包装方法来实现该装置的无缝线植入。体外测试结果表明,螺旋管设计的IOP传感器的角灵敏度为0.67度/mmHg,长臂管设计的横向灵敏度为3.43 μ m/mmHg,蛇形管设计的纵向灵敏度为0.38 μ m/mmHg。该IOP传感器被设计植入眼球前房,直接固定在虹膜上,在入射可见光下,可以从眼外直接观察到植入物的压力响应,从而实现对青光眼患者的忠实和无动力IOP监测
{"title":"Implantable Unpowered Parylene MEMS Intraocular Pressure Sensor","authors":"P.-J. Chen, D. Rodger, E. Meng, M. Humayun, Y. Tai","doi":"10.1109/MMB.2006.251543","DOIUrl":"https://doi.org/10.1109/MMB.2006.251543","url":null,"abstract":"This paper presents the first implantable, unpowered, parylene-based micro-electro-mechanical-systems (MEMS) pressure sensor for intraocular pressure (IOP) sensing. From in situ mechanical deformation of the compliant structures, this sensor registers pressure variations without power consumption/transduction. Micromachined high-aspect-ratio thin-walled tubes in different geometric layouts are exploited to obtain a high-sensitivity pressure response. An integrated packaging method has been successfully developed to realize suture-less implantation of the device. In vitro testing results have demonstrated that the IOP sensor can achieve 0.67 degree/mmHg angular sensitivity with a spiral-tube design, 3.43 mum/mmHg lateral sensitivity with a long-armed-tube design, and 0.38 mum/mmHg longitudinal sensitivity with a serpentine-tube design. This IOP sensor is designed to be implanted in the anterior chamber of the eye and anchored directly on the iris so that, under incident visible light, the pressure response of the implant can be directly observed from outside the eye, which enables faithful and unpowered IOP monitoring in glaucoma patients","PeriodicalId":170356,"journal":{"name":"2006 International Conference on Microtechnologies in Medicine and Biology","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127208129","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 15
Microfluidic Valve Employing the pH-Responsive Hydrogel Microsphere as an Actuating Element 采用ph响应水凝胶微球作为驱动元件的微流体阀
Pub Date : 2006-05-09 DOI: 10.1109/MMB.2006.251483
Ji Young Park, Duck-Joong Kim, Sung Rak Kim, J. Baek, K. Sun, Sang Hoon Lee
In this paper, we propose a new fabrication method of pH-responsive microfluidic valves and suggest the feasibility as a microminiature systems without peripheral devices. Conventionally, in-situ photopolymerization method has been employed to build the micro functional structure inside microfluidic channel. Here, we suggest a new method allowing the mass production of stimuli-responsive microsystem through the use of pre-made microstructure as actuating element like assembly of commercial products in the factory. We have massively fabricated pH-responsive microspheres that act as actuating component through the use of PDMS-based microfluidic apparatus and 'on the fly' photopolymerization method. By the incorporation of this microsphere into the microvalve during the fabrication process, we have produced the pH-responsive microfluidic valve in a simple way. The operation and the function of the fabricated microvalve were evaluated through the diverse experiments. The microvalve was successfully fabricated, and functioned well according to the pH change
在本文中,我们提出了一种新的ph响应微流体阀的制造方法,并提出了其作为微微型系统的可行性。传统的原位光聚合方法是构建微流控通道内部的微功能结构。在这里,我们提出了一种新的方法,通过使用预制微结构作为驱动元件,像在工厂中组装商业产品一样,允许大规模生产刺激响应微系统。通过使用基于pdm的微流体装置和“动态”光聚合方法,我们大量制造了ph响应微球,作为驱动组件。通过在制造过程中将这种微球结合到微阀中,我们以一种简单的方式生产了ph响应微流体阀。通过各种实验对制备的微阀的工作性能和功能进行了评价。该微阀制备成功,并能根据pH值的变化发挥良好的作用
{"title":"Microfluidic Valve Employing the pH-Responsive Hydrogel Microsphere as an Actuating Element","authors":"Ji Young Park, Duck-Joong Kim, Sung Rak Kim, J. Baek, K. Sun, Sang Hoon Lee","doi":"10.1109/MMB.2006.251483","DOIUrl":"https://doi.org/10.1109/MMB.2006.251483","url":null,"abstract":"In this paper, we propose a new fabrication method of pH-responsive microfluidic valves and suggest the feasibility as a microminiature systems without peripheral devices. Conventionally, in-situ photopolymerization method has been employed to build the micro functional structure inside microfluidic channel. Here, we suggest a new method allowing the mass production of stimuli-responsive microsystem through the use of pre-made microstructure as actuating element like assembly of commercial products in the factory. We have massively fabricated pH-responsive microspheres that act as actuating component through the use of PDMS-based microfluidic apparatus and 'on the fly' photopolymerization method. By the incorporation of this microsphere into the microvalve during the fabrication process, we have produced the pH-responsive microfluidic valve in a simple way. The operation and the function of the fabricated microvalve were evaluated through the diverse experiments. The microvalve was successfully fabricated, and functioned well according to the pH change","PeriodicalId":170356,"journal":{"name":"2006 International Conference on Microtechnologies in Medicine and Biology","volume":"68 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126654196","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Performance of Parylene-Packaged Flexible Pentacene Thin-Film Transistors in Saline 盐水中聚苯二烯封装柔性五苯薄膜晶体管的性能
Pub Date : 2006-05-09 DOI: 10.1109/MMB.2006.251499
H. Lo, Y. Tai
A micro-fabricated parylene-packaged flexible pentacene thin film transistor is presented. Different from preceding devices that have been reported, this thin film transistor employs parylene as the substrate, the gate insulator and also the top protection layer. Also, this thin film transistor uses pentacene, an organic semiconductor with high mobility, as the active material. The fresh made thin film transistor shows a hole mobility of 0.022 cm2/V-s. In spite of initial drops, the transistor's hole mobility stays at 0.001 cm2/V-s after over 6-month soaking in saline. We can conclude that drifts in mobility from soaking do exist but they saturate to values still of promise In addition, we believe there's plenty of room to improve the parylene packaging such as by using thicker parylene (this work used only 1mum)
提出了一种微加工聚苯二烯封装柔性五苯薄膜晶体管。与之前报道的器件不同,这种薄膜晶体管采用聚对二甲苯作为衬底、栅极绝缘体和顶部保护层。此外,这种薄膜晶体管使用了具有高迁移率的有机半导体并五苯作为活性材料。该薄膜晶体管的空穴迁移率为0.022 cm2/V-s。在盐水中浸泡6个月后,晶体管的空穴迁移率保持在0.001 cm2/V-s。我们可以得出结论,从浸泡到迁移率的漂移确实存在,但它们饱和到仍然有希望的值。此外,我们认为有足够的空间来改进聚二甲苯包装,例如使用更厚的聚二甲苯(本工作仅使用了1mum)。
{"title":"Performance of Parylene-Packaged Flexible Pentacene Thin-Film Transistors in Saline","authors":"H. Lo, Y. Tai","doi":"10.1109/MMB.2006.251499","DOIUrl":"https://doi.org/10.1109/MMB.2006.251499","url":null,"abstract":"A micro-fabricated parylene-packaged flexible pentacene thin film transistor is presented. Different from preceding devices that have been reported, this thin film transistor employs parylene as the substrate, the gate insulator and also the top protection layer. Also, this thin film transistor uses pentacene, an organic semiconductor with high mobility, as the active material. The fresh made thin film transistor shows a hole mobility of 0.022 cm2/V-s. In spite of initial drops, the transistor's hole mobility stays at 0.001 cm2/V-s after over 6-month soaking in saline. We can conclude that drifts in mobility from soaking do exist but they saturate to values still of promise In addition, we believe there's plenty of room to improve the parylene packaging such as by using thicker parylene (this work used only 1mum)","PeriodicalId":170356,"journal":{"name":"2006 International Conference on Microtechnologies in Medicine and Biology","volume":"41 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121677476","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Study of the Quasi-Canonical Localized Orbital (QCLO) Method Based on Protein Structures 基于蛋白质结构的准正则定域轨道(QCLO)方法研究
Pub Date : 2006-05-09 DOI: 10.1109/MMB.2006.251541
N. Nishino, T. Hirano, T. Nishimura, S. Koike, F. Sato
We have developed a density functional (DF) program, ProteinDF, for all-electron calculation on proteins. In order to overcome difficulties of a convergence problem in large-scale molecules, we have already proposed new localized orbital (LO), which named quasi-canonical LO (QCLO). In this study, improved convergence process which focused on the secondary structure such as hydrogen bonds and salt-bridge is proposed. The effectiveness of the improved process was discussed by comparing with the values of the original method, i.e. the total energy, convergence history and difference of Mulliken populations between initial and converged states. We proved the new convergence processes gave significantly better initial guess than previous one. This method could be useful for safe and automatic all-electron DF calculations on very large-scale proteins
我们开发了一个密度泛函(DF)程序,ProteinDF,用于蛋白质的全电子计算。为了克服大尺度分子收敛问题的困难,我们提出了一种新的局域轨道(LO),称为准正则轨道(QCLO)。本研究提出了以氢键和盐桥等二级结构为中心的改进收敛过程。通过与原方法的总能量、收敛历史和初始状态与收敛状态之间的Mulliken种群差值进行比较,讨论了改进过程的有效性。我们证明了新的收敛过程比以前的收敛过程给出了更好的初始猜测。该方法可用于非常大规模蛋白质的安全、自动全电子DF计算
{"title":"Study of the Quasi-Canonical Localized Orbital (QCLO) Method Based on Protein Structures","authors":"N. Nishino, T. Hirano, T. Nishimura, S. Koike, F. Sato","doi":"10.1109/MMB.2006.251541","DOIUrl":"https://doi.org/10.1109/MMB.2006.251541","url":null,"abstract":"We have developed a density functional (DF) program, ProteinDF, for all-electron calculation on proteins. In order to overcome difficulties of a convergence problem in large-scale molecules, we have already proposed new localized orbital (LO), which named quasi-canonical LO (QCLO). In this study, improved convergence process which focused on the secondary structure such as hydrogen bonds and salt-bridge is proposed. The effectiveness of the improved process was discussed by comparing with the values of the original method, i.e. the total energy, convergence history and difference of Mulliken populations between initial and converged states. We proved the new convergence processes gave significantly better initial guess than previous one. This method could be useful for safe and automatic all-electron DF calculations on very large-scale proteins","PeriodicalId":170356,"journal":{"name":"2006 International Conference on Microtechnologies in Medicine and Biology","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131279184","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
ProteinEditor: Integrated Environment for Quantum Chemical Calculation System for Proteins ProteinEditor:蛋白质量子化学计算系统的集成环境
Pub Date : 2006-05-09 DOI: 10.1109/MMB.2006.251481
Y. Nishimura, T. Yoshihiro, N. Nishino, F. Sato
We have developed the quantum chemical calculation system for proteins based on the density functional method program ProteinDF. This system is composed of five subsystems: "Automatic computations", "Geometry optimization and ab initio molecular dynamics (MD) calculation (Quantum dynamics)", "Calculations on very large-sized proteins", "Database of protein wavefunctions", and "Integrated environment, ProteinEditor". In this study, we will report the development of ProteinEditor subsystem. In all-electron calculations on proteins, the data size is huge and the simulation becomes complex. Therefore, an interactive and easy control by the user is indispensable. To reduce these problems, ProteinEditor contains a graphical user interface (GUI) to support the all-electron semi-automatic calculation method for proteins (QCLO method). The structural interaction representation functions cooperated with the high-performance molecular graphics can assist the safe quantum chemical calculation. We also implemented the functions of hydrogen addition, the amino acid substitution (point mutation) and checking the structural validity of proteins in PDB format. This work will guarantee the easy and safe achievement of quantum chemical simulation of proteins
我们开发了基于密度泛函方法程序ProteinDF的蛋白质量子化学计算系统。该系统由“自动计算”、“几何优化与从头算分子动力学(MD)计算(量子动力学)”、“超大尺寸蛋白质计算”、“蛋白质波函数数据库”和“集成环境,ProteinEditor”五个子系统组成。在这项研究中,我们将报告ProteinEditor子系统的开发。在蛋白质的全电子计算中,数据量巨大,模拟变得复杂。因此,一种易于用户交互的控制方式是必不可少的。为了减少这些问题,ProteinEditor包含一个图形用户界面(GUI)来支持全电子半自动计算蛋白质的方法(QCLO方法)。结构相互作用表示函数与高性能分子图形相结合,可辅助安全量子化学计算。我们还实现了加氢、氨基酸取代(点突变)和PDB格式蛋白质结构有效性检查的功能。这项工作将保证简单、安全地实现蛋白质的量子化学模拟
{"title":"ProteinEditor: Integrated Environment for Quantum Chemical Calculation System for Proteins","authors":"Y. Nishimura, T. Yoshihiro, N. Nishino, F. Sato","doi":"10.1109/MMB.2006.251481","DOIUrl":"https://doi.org/10.1109/MMB.2006.251481","url":null,"abstract":"We have developed the quantum chemical calculation system for proteins based on the density functional method program ProteinDF. This system is composed of five subsystems: \"Automatic computations\", \"Geometry optimization and ab initio molecular dynamics (MD) calculation (Quantum dynamics)\", \"Calculations on very large-sized proteins\", \"Database of protein wavefunctions\", and \"Integrated environment, ProteinEditor\". In this study, we will report the development of ProteinEditor subsystem. In all-electron calculations on proteins, the data size is huge and the simulation becomes complex. Therefore, an interactive and easy control by the user is indispensable. To reduce these problems, ProteinEditor contains a graphical user interface (GUI) to support the all-electron semi-automatic calculation method for proteins (QCLO method). The structural interaction representation functions cooperated with the high-performance molecular graphics can assist the safe quantum chemical calculation. We also implemented the functions of hydrogen addition, the amino acid substitution (point mutation) and checking the structural validity of proteins in PDB format. This work will guarantee the easy and safe achievement of quantum chemical simulation of proteins","PeriodicalId":170356,"journal":{"name":"2006 International Conference on Microtechnologies in Medicine and Biology","volume":"114 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133831679","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
2006 International Conference on Microtechnologies in Medicine and Biology
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1