Recent results with a CdTe imaging portal scanner for radiation therapy 最近的结果与CdTe成像门静脉扫描仪放射治疗
Pub Date : 1992-10-25 DOI: 10.1109/NSSMIC.1992.301535
G. Entine, R. Redus, A. Feyder, P. Biggs
A prototype portal imager has been constructed using a linear array of 256 CdTe photovoltaic detectors, each 2*2*2 mm. The array is attached to a compact linear scanner which is to be mounted in a cassette-shaped package located below the patient table. The array of detectors is moved under the patient during image acquisition. The high stopping power of CdTe allows a high-contrast image to be made using a single linac pulse for each array position. In tests conducted with a 4 MV linac, this system produced 50 cm*35 cm near-real-time images with an open field signal-to-noise ratio (SNR) of 143 and 2 mm spatial resolution in less than three seconds. This corresponds to a SNR of 1 for 1% contrast objects. Ultimately, a SNR greater than 5 at 1% contrast should be achievable with no loss of spatial resolution or increase in acquisition time.<>
使用256个CdTe光伏探测器线性阵列构建了一个原型门户成像仪,每个探测器为2*2*2 mm。该阵列连接到一个紧凑的线性扫描仪上,该扫描仪将安装在位于患者桌子下方的盒式包装中。在图像采集过程中,检测器阵列在患者下方移动。CdTe的高阻挡能力允许使用单个直线脉冲为每个阵列位置制作高对比度图像。在4 MV直线加速器上进行的测试中,该系统在不到3秒的时间内生成了50 cm*35 cm的近实时图像,开放场信噪比(SNR)为143,空间分辨率为2mm。这对应于1%对比度对象的信噪比为1。最终,在不损失空间分辨率或增加采集时间的情况下,在1%对比度下的信噪比应该大于5。
{"title":"Recent results with a CdTe imaging portal scanner for radiation therapy","authors":"G. Entine, R. Redus, A. Feyder, P. Biggs","doi":"10.1109/NSSMIC.1992.301535","DOIUrl":"https://doi.org/10.1109/NSSMIC.1992.301535","url":null,"abstract":"A prototype portal imager has been constructed using a linear array of 256 CdTe photovoltaic detectors, each 2*2*2 mm. The array is attached to a compact linear scanner which is to be mounted in a cassette-shaped package located below the patient table. The array of detectors is moved under the patient during image acquisition. The high stopping power of CdTe allows a high-contrast image to be made using a single linac pulse for each array position. In tests conducted with a 4 MV linac, this system produced 50 cm*35 cm near-real-time images with an open field signal-to-noise ratio (SNR) of 143 and 2 mm spatial resolution in less than three seconds. This corresponds to a SNR of 1 for 1% contrast objects. Ultimately, a SNR greater than 5 at 1% contrast should be achievable with no loss of spatial resolution or increase in acquisition time.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126801880","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 20
Development of novel architecture and assembly techniques for a detector unit for a silicon micro-vertex detector using the flip-chip bonding method 采用倒装片键合方法的硅微顶点检测器检测器单元的新结构和组装技术的发展
Pub Date : 1992-10-25 DOI: 10.1109/NSSMIC.1992.301207
Y. Saitoh, J. Yamanaka, H. Suzuki, S. Miyahara, M. Kamiya, K. Kadoi, T. Masusda, K. Maemura, M. Inoue, A. Suzuki, H. Takeuchi, M. Mandai, H. Kanazawa, Y. Higashi, H. Ikeda, S. Koike, T. Matsuda, H. Ozaki, M. Tanaka, T. Tsuboyama, S. Avrillon, S. Okuno, J. Haba, H. Hamai, S. Mori, K. Yusa
Full-size models of a detector unit for a silicon microvertex detector for the KEK B factory have been built. The model consists of four dummy double-sided, double-metal silicon microstrip detectors and two silicon end-boards mounted with dummy readout VLSIs on both sides. In this trial the flip-chip bonding method, using an anisotropic conductive film, is applied to both sides of the detector unit to bond 640 strips at a pitch of 50 mu m.<>
为KEK B工厂建立了硅微顶点探测器单元的全尺寸模型。该模型由四个假的双面双金属硅微带探测器和两个在两侧安装假读出vlsi的硅端板组成。在本试验中,使用各向异性导电膜的倒装片键合方法应用于检测器单元的两侧,以50 μ m的间距键合640条条带。
{"title":"Development of novel architecture and assembly techniques for a detector unit for a silicon micro-vertex detector using the flip-chip bonding method","authors":"Y. Saitoh, J. Yamanaka, H. Suzuki, S. Miyahara, M. Kamiya, K. Kadoi, T. Masusda, K. Maemura, M. Inoue, A. Suzuki, H. Takeuchi, M. Mandai, H. Kanazawa, Y. Higashi, H. Ikeda, S. Koike, T. Matsuda, H. Ozaki, M. Tanaka, T. Tsuboyama, S. Avrillon, S. Okuno, J. Haba, H. Hamai, S. Mori, K. Yusa","doi":"10.1109/NSSMIC.1992.301207","DOIUrl":"https://doi.org/10.1109/NSSMIC.1992.301207","url":null,"abstract":"Full-size models of a detector unit for a silicon microvertex detector for the KEK B factory have been built. The model consists of four dummy double-sided, double-metal silicon microstrip detectors and two silicon end-boards mounted with dummy readout VLSIs on both sides. In this trial the flip-chip bonding method, using an anisotropic conductive film, is applied to both sides of the detector unit to bond 640 strips at a pitch of 50 mu m.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"62 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114919394","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Increasing the axial extent in volume imaging PET scanners: Is there a limit? a Monte Carlo study 增加PET容积成像扫描仪的轴向范围:有限制吗?蒙特卡洛研究
Pub Date : 1992-10-25 DOI: 10.1109/NSSMIC.1992.301018
R. Freifelder, J. Karp
A Monte Carlo simulation program for the PENN-PET (University of Pennsylvania positron emission tomography) scanner design is presented. The program is flexible enough to allow one to vary the geometry and study the effects of increasing the axial extent of the scanner. The authors present a series of Monte Carlo studies comparing two volume imaging scanners currently being used which differ only in their axial extent (9.0 cm and 13.5 cm). They also present predictions of the performance of a similar body scanner with a 25.6 cm axial extent and a head-only scanner, also having a 25.6 cm axial extent but with a reduced radius which greatly increases the solid angle of the detectors. The studies show the effects of increasing the axial extent on the trues, scatters, randoms, and overall system sensitivity. It is shown that the scatter fraction does not change significantly as the axial extent of the scanner is increased, especially when an appropriate definition for scatter is taken into account. The ratio of randoms/trues decreases with increasing axial extent as a function of the activity.<>
介绍了宾夕法尼亚大学正电子发射层析成像(PENN-PET)扫描仪设计的蒙特卡罗模拟程序。该程序是灵活的,足以允许一个改变几何形状,并研究增加扫描仪的轴向范围的影响。作者介绍了一系列蒙特卡罗研究,比较了目前使用的两种体积成像扫描仪,它们仅在轴向范围(9.0厘米和13.5厘米)上有所不同。他们还预测了一种轴向25.6厘米的类似人体扫描仪和一种仅用于头部的扫描仪的性能,也具有25.6厘米的轴向范围,但半径减小,大大增加了探测器的立体角。研究表明增加轴向范围对真值、散点、随机值和系统整体灵敏度的影响。结果表明,散射分数随着扫描仪轴向范围的增加而变化不大,特别是当考虑到散射的适当定义时。随轴向范围的增加,随机/真比值随活度的增加而减小
{"title":"Increasing the axial extent in volume imaging PET scanners: Is there a limit? a Monte Carlo study","authors":"R. Freifelder, J. Karp","doi":"10.1109/NSSMIC.1992.301018","DOIUrl":"https://doi.org/10.1109/NSSMIC.1992.301018","url":null,"abstract":"A Monte Carlo simulation program for the PENN-PET (University of Pennsylvania positron emission tomography) scanner design is presented. The program is flexible enough to allow one to vary the geometry and study the effects of increasing the axial extent of the scanner. The authors present a series of Monte Carlo studies comparing two volume imaging scanners currently being used which differ only in their axial extent (9.0 cm and 13.5 cm). They also present predictions of the performance of a similar body scanner with a 25.6 cm axial extent and a head-only scanner, also having a 25.6 cm axial extent but with a reduced radius which greatly increases the solid angle of the detectors. The studies show the effects of increasing the axial extent on the trues, scatters, randoms, and overall system sensitivity. It is shown that the scatter fraction does not change significantly as the axial extent of the scanner is increased, especially when an appropriate definition for scatter is taken into account. The ratio of randoms/trues decreases with increasing axial extent as a function of the activity.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"280 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115332589","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
A bounded error estimation approach to image reconstruction 图像重建的有界误差估计方法
Pub Date : 1992-10-25 DOI: 10.1109/NSSMIC.1992.301091
Ying Zhang, A. Hero, W. Rogers
A bounded error (BE) approach to image reconstruction is investigated. In this approach a bound on the measured projections errors is specified and the set of images which is consistent with both the data and the error bound is constructed. The error bound can account for both statistical noise uncertainty, e.g., due to randoms correction or other Poisson-destructive preprocessing, and model uncertainty, e.g., due to a mismodeled or uncalibrated system matrix. The consistent set of images is a set estimate of the image from which point estimates, i.e., image reconstructions can be selected.<>
研究了一种基于有界误差的图像重建方法。该方法对测量的投影误差设定一个界,并构造与数据和误差界一致的图像集。误差范围可以解释统计噪声的不确定性,例如,由于随机校正或其他泊松破坏性预处理,以及模型的不确定性,例如,由于错误建模或未校准的系统矩阵。一致图像集是图像的一个集合估计,从中可以选择点估计,即图像重建。
{"title":"A bounded error estimation approach to image reconstruction","authors":"Ying Zhang, A. Hero, W. Rogers","doi":"10.1109/NSSMIC.1992.301091","DOIUrl":"https://doi.org/10.1109/NSSMIC.1992.301091","url":null,"abstract":"A bounded error (BE) approach to image reconstruction is investigated. In this approach a bound on the measured projections errors is specified and the set of images which is consistent with both the data and the error bound is constructed. The error bound can account for both statistical noise uncertainty, e.g., due to randoms correction or other Poisson-destructive preprocessing, and model uncertainty, e.g., due to a mismodeled or uncalibrated system matrix. The consistent set of images is a set estimate of the image from which point estimates, i.e., image reconstructions can be selected.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"44 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115578547","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
An X-ray microtomography system for bone structure measurements 用于骨结构测量的x射线微断层扫描系统
Pub Date : 1992-10-25 DOI: 10.1109/NSSMIC.1992.301514
M. Flynn, D. Reimann, A. Parfitt, D. Fyhrie
A system for very-high-resolution (50 mu m*50 mu m*50 mu m) three-dimensional tomography of small (1 cm*1 cm*1 cm) biological specimen is described. Two-dimensional planar X-ray views of the specimen are acquired by an image intensifier and digital camera system while the specimen is rotated through several hundred positions. The recorded data are processed to obtain spatially accurate estimates of the attenuation line integral and reconstructed using a cone-beam algorithm. Measurements obtained with this system are being used to study the structures found in bone biopsy specimens.<>
描述了一种用于小型(1cm * 1cm * 1cm)生物标本的高分辨率(50 μ m*50 μ m*50 μ m)三维断层扫描系统。样品的二维平面x射线视图由图像增强器和数码相机系统获得,同时样品通过数百个位置旋转。对记录的数据进行处理以获得衰减线积分的空间精确估计,并使用锥束算法进行重建。使用该系统获得的测量结果被用于研究骨活检标本中的结构。
{"title":"An X-ray microtomography system for bone structure measurements","authors":"M. Flynn, D. Reimann, A. Parfitt, D. Fyhrie","doi":"10.1109/NSSMIC.1992.301514","DOIUrl":"https://doi.org/10.1109/NSSMIC.1992.301514","url":null,"abstract":"A system for very-high-resolution (50 mu m*50 mu m*50 mu m) three-dimensional tomography of small (1 cm*1 cm*1 cm) biological specimen is described. Two-dimensional planar X-ray views of the specimen are acquired by an image intensifier and digital camera system while the specimen is rotated through several hundred positions. The recorded data are processed to obtain spatially accurate estimates of the attenuation line integral and reconstructed using a cone-beam algorithm. Measurements obtained with this system are being used to study the structures found in bone biopsy specimens.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"316 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122785727","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Comparison of two fast reconstruction methods for a cylindrical PET camera 圆柱形PET相机两种快速重建方法的比较
Pub Date : 1992-10-25 DOI: 10.1109/NSSMIC.1992.301011
M. Grégoire, D. Chesler
The authors compare the accuracy and precision of two fast reconstruction methods for a cylindrical PET (positron emission tomography) camera. One method is based on the estimation of the missing data; the other uses different amounts of data to reconstruct each slice. Both methods are implemented in the frequency domain and run on realistic data in less than two hours. Their intrinsic quality is quite similar. In the presence of statistical noise, there is no significant difference between the methods. One could therefore prefer to use the interpolative reconstruction for a small centered activity distribution like a receptor study, while reserving the Favor procedure for a large distribution pattern like a cerebral blood flow study. This study has been carried out on the model of the cylindrical PET camera under development at the Massachusetts General Hospital.<>
比较了圆柱正电子发射断层成像(PET)相机两种快速重建方法的准确度和精密度。一种方法是基于缺失数据的估计;另一种方法使用不同数量的数据来重建每个切片。这两种方法都是在频域中实现的,并且在不到两个小时的时间内运行在实际数据上。它们的内在品质非常相似。在存在统计噪声的情况下,两种方法之间没有显著差异。因此,对于像受体研究这样的小中心活动分布,人们可能更倾向于使用插值重建,而对于像脑血流研究这样的大分布模式,则保留偏好程序。这项研究是在麻省总医院正在开发的圆柱形PET相机模型上进行的。
{"title":"Comparison of two fast reconstruction methods for a cylindrical PET camera","authors":"M. Grégoire, D. Chesler","doi":"10.1109/NSSMIC.1992.301011","DOIUrl":"https://doi.org/10.1109/NSSMIC.1992.301011","url":null,"abstract":"The authors compare the accuracy and precision of two fast reconstruction methods for a cylindrical PET (positron emission tomography) camera. One method is based on the estimation of the missing data; the other uses different amounts of data to reconstruct each slice. Both methods are implemented in the frequency domain and run on realistic data in less than two hours. Their intrinsic quality is quite similar. In the presence of statistical noise, there is no significant difference between the methods. One could therefore prefer to use the interpolative reconstruction for a small centered activity distribution like a receptor study, while reserving the Favor procedure for a large distribution pattern like a cerebral blood flow study. This study has been carried out on the model of the cylindrical PET camera under development at the Massachusetts General Hospital.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"70 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122924963","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Two fast data acquisition and processing systems for a compact gamma-camera 两个快速数据采集和处理系统,用于紧凑型伽玛相机
Pub Date : 1992-10-25 DOI: 10.1109/NSSMIC.1992.301069
Z. He, D. Ramsden, S. Holder, S. H. Duncan
A compact gamma-camera has been constructed using a 3-mm-thick single NaI(Tl) crystal viewed by a 5-in-diameter Hamamatsu position-sensitive photomultiplier tube (R3292). In order to use this system in applications where the counting rate is high, such as in dynamic scintigraphy and industrial nondestructive testing, a fast data acquisition and processing system is very important. The design and operation of two fast data collection and processing systems capable of handling events within 30 mu s are presented. One of the systems is based on the use of a commercial Vector 32C/8500 processor board, while the other makes use of multiple T805 transputers. A comparison of the two systems is presented.<>
利用直径5英寸的Hamamatsu位置敏感光电倍增管(R3292)观察3毫米厚的单NaI(Tl)晶体,构建了一种紧凑的伽玛相机。为了使该系统在动态闪烁和工业无损检测等计数率较高的应用中使用,一个快速的数据采集和处理系统是非常重要的。介绍了两套能处理30亩内事件的快速数据采集与处理系统的设计和运行情况。其中一个系统基于使用商用矢量32C/8500处理器板,而另一个系统则使用多个T805转发器。对这两种系统进行了比较。
{"title":"Two fast data acquisition and processing systems for a compact gamma-camera","authors":"Z. He, D. Ramsden, S. Holder, S. H. Duncan","doi":"10.1109/NSSMIC.1992.301069","DOIUrl":"https://doi.org/10.1109/NSSMIC.1992.301069","url":null,"abstract":"A compact gamma-camera has been constructed using a 3-mm-thick single NaI(Tl) crystal viewed by a 5-in-diameter Hamamatsu position-sensitive photomultiplier tube (R3292). In order to use this system in applications where the counting rate is high, such as in dynamic scintigraphy and industrial nondestructive testing, a fast data acquisition and processing system is very important. The design and operation of two fast data collection and processing systems capable of handling events within 30 mu s are presented. One of the systems is based on the use of a commercial Vector 32C/8500 processor board, while the other makes use of multiple T805 transputers. A comparison of the two systems is presented.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"125 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114426653","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A charge sensitive preamplifier based on GaAs heterojunction bipolar transistors 基于砷化镓异质结双极晶体管的电荷敏感前置放大器
Pub Date : 1992-10-25 DOI: 10.1109/NSSMIC.1992.301277
C. Buttar, S. Walker, K. Shankar
Summary form only. The application of GaAs technology to particle physics experiments has been investigated. It appears that GaAs heterojunction bipolar transistors (HBT) might suit the requirements for the front end electronics, such as radiation hardness and adequate gm at very low current for low power dissipation and at fast shaping times. Since the operation of an HBT is similar to that of a silicon bipolar transistor, general analog simulators, such as SPICE, could be used to simulate HBT designs. A preamplifier design with RC-CR shaping has been developed, and a prototype has been fabricated using surface mount technology and discrete HBTs.<>
只有摘要形式。研究了砷化镓技术在粒子物理实验中的应用。似乎GaAs异质结双极晶体管(HBT)可能适合前端电子器件的要求,例如辐射硬度和在非常低的电流下足够的gm,以实现低功耗和快速成型时间。由于HBT的操作类似于硅双极晶体管,一般的模拟模拟器,如SPICE,可以用来模拟HBT设计。开发了一种RC-CR成形前置放大器设计,并使用表面贴装技术和离散hbt制造了一个原型。
{"title":"A charge sensitive preamplifier based on GaAs heterojunction bipolar transistors","authors":"C. Buttar, S. Walker, K. Shankar","doi":"10.1109/NSSMIC.1992.301277","DOIUrl":"https://doi.org/10.1109/NSSMIC.1992.301277","url":null,"abstract":"Summary form only. The application of GaAs technology to particle physics experiments has been investigated. It appears that GaAs heterojunction bipolar transistors (HBT) might suit the requirements for the front end electronics, such as radiation hardness and adequate gm at very low current for low power dissipation and at fast shaping times. Since the operation of an HBT is similar to that of a silicon bipolar transistor, general analog simulators, such as SPICE, could be used to simulate HBT designs. A preamplifier design with RC-CR shaping has been developed, and a prototype has been fabricated using surface mount technology and discrete HBTs.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121865999","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Data collection circuit for the SDC straw tube tracker 用于SDC吸管跟踪器的数据采集电路
Pub Date : 1992-10-25 DOI: 10.1109/NSSMIC.1992.301317
G. Stairs, A. Holscher, P. Sinervo, K. Ragan
The architecture and design of a data collection circuit for the Solenoid Detector Collaboration (SDC) Outer Tracker is described. The DCC system reads out 141404 straws, and feeds them via 16 links into the data-acquisition event builder. It also performs monitoring and error handling functions. An overview of the DCC architecture, results from simulations, and comments on the status of the prototype program that is currently under way are presented.<>
介绍了一种用于电磁检测器协同(SDC)外部跟踪器的数据采集电路的结构和设计。DCC系统读出141404个吸管,并通过16个链接将它们提供给数据采集事件构建器。它还执行监视和错误处理功能。概述了DCC体系结构,仿真结果,并对目前正在进行的原型程序的状态进行了评论。
{"title":"Data collection circuit for the SDC straw tube tracker","authors":"G. Stairs, A. Holscher, P. Sinervo, K. Ragan","doi":"10.1109/NSSMIC.1992.301317","DOIUrl":"https://doi.org/10.1109/NSSMIC.1992.301317","url":null,"abstract":"The architecture and design of a data collection circuit for the Solenoid Detector Collaboration (SDC) Outer Tracker is described. The DCC system reads out 141404 straws, and feeds them via 16 links into the data-acquisition event builder. It also performs monitoring and error handling functions. An overview of the DCC architecture, results from simulations, and comments on the status of the prototype program that is currently under way are presented.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121983633","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Copper-scintillating fiber hadron calorimeter tower prototypes 铜闪烁光纤强子量热计塔原型
Pub Date : 1992-10-25 DOI: 10.1109/NSSMIC.1992.301223
D. Brown, R. Carey, S. Dye, E. Hazen, D. Higby, J. Miller, L. Sulak, J. Sullivan, W. Worstell, W. Brower, H. Paar, D. Kefford, R. Pisani, K. Segall, D. Wall, D. Winn, N. Akchurin, J. Langland, Y. Onel, J. Sandro, C. Bromberg, R. Miller, B. Moore, J. Reidy, W. Bugg, R. Kroeger, R. Wigmans, F. Ayer, C. Elder, H. Cohn, Y. Kamyshkov, F. Placil, M. Rennich, A. Savin, K. Shmakov, A. Smirnov, K. Young
The authors have constructed and tested seven projective scintillating fiber-copper absorber hadron calorimeter towers for high-energy hadron collider detectors. Each tower contained 2.25% by volume scintillating fibers, embedded between copper laminations, 10.6 lambda deep. A hadron energy resolution of sigma /E=91%/ square root E was obtained. Pions exhibited uniform response when scanned across boundaries between modules and through a range of incident angles with respect to the fibers. The e/ pi ratio is 1.08+or-0.02 for energies between 10 and 20 GeV, with a response of approximately 60 p.e./GeV. The muon Landau distributions well-resolved from pedestals were observed.<>
作者为高能强子对撞机探测器构建并测试了7个投影闪烁光纤-铜吸收体强子量热塔。每个塔包含2.25%的体积闪烁纤维,嵌入在铜层之间,深10.6 λ。得到了sigma /E=91%/平方根E的强子能量分辨率。当扫描穿过模块之间的边界和相对于光纤的一系列入射角时,介子表现出均匀的响应。能量在10到20 GeV之间的e/ pi比值为1.08±0.02,响应约为60 p.e./GeV。观测到从台座上很好地分辨出的μ子朗道分布
{"title":"Copper-scintillating fiber hadron calorimeter tower prototypes","authors":"D. Brown, R. Carey, S. Dye, E. Hazen, D. Higby, J. Miller, L. Sulak, J. Sullivan, W. Worstell, W. Brower, H. Paar, D. Kefford, R. Pisani, K. Segall, D. Wall, D. Winn, N. Akchurin, J. Langland, Y. Onel, J. Sandro, C. Bromberg, R. Miller, B. Moore, J. Reidy, W. Bugg, R. Kroeger, R. Wigmans, F. Ayer, C. Elder, H. Cohn, Y. Kamyshkov, F. Placil, M. Rennich, A. Savin, K. Shmakov, A. Smirnov, K. Young","doi":"10.1109/NSSMIC.1992.301223","DOIUrl":"https://doi.org/10.1109/NSSMIC.1992.301223","url":null,"abstract":"The authors have constructed and tested seven projective scintillating fiber-copper absorber hadron calorimeter towers for high-energy hadron collider detectors. Each tower contained 2.25% by volume scintillating fibers, embedded between copper laminations, 10.6 lambda deep. A hadron energy resolution of sigma /E=91%/ square root E was obtained. Pions exhibited uniform response when scanned across boundaries between modules and through a range of incident angles with respect to the fibers. The e/ pi ratio is 1.08+or-0.02 for energies between 10 and 20 GeV, with a response of approximately 60 p.e./GeV. The muon Landau distributions well-resolved from pedestals were observed.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"91 2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116694317","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
期刊
IEEE Conference on Nuclear Science Symposium and Medical Imaging
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1