首页 > 最新文献

International Journal of The Japan Society for Precision Engineering最新文献

英文 中文
Correction of specimen orientation in three-dimensional measurement of surface roughness with small waviness by contact stylus instrument (2nd report) : simulation and experimental verification 接触式触针仪小波浪形表面粗糙度三维测量中试样取向的校正(第2报告):仿真与实验验证
Pub Date : 1994-01-01 DOI: 10.2493/JJSPE.60.549
N. Cho, T. Tsukada, M. Takahashi
In this paper, the method I is compared with the method II. The method I is developed in the 1st report to control surface orientation by using two measuring lines perpendicular to each other and the method II by two parallel measuring lines. The results are as follows . (1)The measuring length for control data in the method I increases for anisotropic rough surface under the condition that the angle between measuring direction and lay orientation of asperities is less than 15•K . (2)The measuring length for control data in the method II decreases as the coefficient k2 depending on a stylus speed decreases. (3)Both of the measuring length and the objective function showing measuring time in the method II are shorter than those in the method I for isotropic and anisotropic rough surfaces . Finally, the method II is better technique than the method I .
本文将方法一与方法二进行了比较。在第一篇报告中提出了用两条互相垂直的测量线来控制曲面方向的方法一和用两条平行的测量线来控制曲面方向的方法二。结果如下:(1)对于各向异性粗糙表面,方法1中控制数据的测量长度在凹凸点测量方向与铺设方向夹角小于15•K的情况下有所增加。(2)方法II中控制数据的测量长度随着依赖触控笔速度的系数k2的减小而减小。(3)对于各向同性和各向异性粗糙表面,方法II的测量长度和显示测量时间的目标函数都比方法I短。最后,方法二是优于方法一的技术。
{"title":"Correction of specimen orientation in three-dimensional measurement of surface roughness with small waviness by contact stylus instrument (2nd report) : simulation and experimental verification","authors":"N. Cho, T. Tsukada, M. Takahashi","doi":"10.2493/JJSPE.60.549","DOIUrl":"https://doi.org/10.2493/JJSPE.60.549","url":null,"abstract":"In this paper, the method I is compared with the method II. The method I is developed in the 1st report to control surface orientation by using two measuring lines perpendicular to each other and the method II by two parallel measuring lines. The results are as follows . (1)The measuring length for control data in the method I increases for anisotropic rough surface under the condition that the angle between measuring direction and lay orientation of asperities is less than 15•K . (2)The measuring length for control data in the method II decreases as the coefficient k2 depending on a stylus speed decreases. (3)Both of the measuring length and the objective function showing measuring time in the method II are shorter than those in the method I for isotropic and anisotropic rough surfaces . Finally, the method II is better technique than the method I .","PeriodicalId":14336,"journal":{"name":"International Journal of The Japan Society for Precision Engineering","volume":"4 1","pages":"253-258"},"PeriodicalIF":0.0,"publicationDate":"1994-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90049486","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of Micro-cracks in Layer on Performance of CVD Coating Carbide Cutting Tool. 层内微裂纹对CVD涂层硬质合金刀具性能的影响
Pub Date : 1994-01-01 DOI: 10.2493/JJSPE.60.124
S. Katayama, Masayuki Hashimura
Micro-cracks were mechanically induced in the CVD coating layers on a cemented carbide tool . With decreasing mean value of distance between cracks from 200 ƒÊm to 20 ƒÊm, tensile residual stress in the coating decreased from 0.55 GPa to 0.05 GPa, the initiation time of thermal fatigue cracks in face milling became longer, and the chipping resistance in interrupted cutting tripled. It seems that the improvement of tool performance is closely related to the relief of tensile residual stress in the coating.
在硬质合金刀具CVD涂层中机械诱发微裂纹。随着裂纹间距平均值从200 ƒÊm减小到20 ƒÊm,涂层中残余拉伸应力从0.55 GPa减小到0.05 GPa,面铣削热疲劳裂纹萌生时间变长,断口切削抗切屑能力增加3倍。结果表明,刀具性能的提高与涂层中残余拉伸应力的消除密切相关。
{"title":"Effect of Micro-cracks in Layer on Performance of CVD Coating Carbide Cutting Tool.","authors":"S. Katayama, Masayuki Hashimura","doi":"10.2493/JJSPE.60.124","DOIUrl":"https://doi.org/10.2493/JJSPE.60.124","url":null,"abstract":"Micro-cracks were mechanically induced in the CVD coating layers on a cemented carbide tool . With decreasing mean value of distance between cracks from 200 ƒÊm to 20 ƒÊm, tensile residual stress in the coating decreased from 0.55 GPa to 0.05 GPa, the initiation time of thermal fatigue cracks in face milling became longer, and the chipping resistance in interrupted cutting tripled. It seems that the improvement of tool performance is closely related to the relief of tensile residual stress in the coating.","PeriodicalId":14336,"journal":{"name":"International Journal of The Japan Society for Precision Engineering","volume":"21 1","pages":"124-127"},"PeriodicalIF":0.0,"publicationDate":"1994-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77788694","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Measurement of surface roughness with small waviness by contact stylus instrument correcting specimen orientation 用校正试样方向的触头仪器测量小波浪形表面粗糙度
Pub Date : 1993-11-05 DOI: 10.2493/JJSPE.59.1871
N. Cho, T. Tsukada, Masaaki Takahashi
This paper presents the new technique to measure the surface roughness profiles correcting an orientation of specimen surface in one operation. The contact stylus profilometer is equipped with the table whose inclination is controlled by the computer. The positioning of the stylus tip in the vertical direction is corrected at the same time. For assuring to measure profiles in length of 5.6mm, the surface profile data for control is demanded to be obtained in the length of 1mm. This measuring length varies depending on form errors such as the waviness. Then this paper gives the new technique to correspond the above-mentioned problem.
本文介绍了一种测量表面粗糙度剖面的新技术,该技术可一次校正试样表面的取向。接触式触针轮廓仪配有由计算机控制其倾斜度的工作台。同时纠正笔尖在垂直方向上的定位。为保证测量5.6mm长度的型材,要求获得长度为1mm的控制面型材数据。这种测量长度取决于形状误差,如波浪度。针对上述问题,本文给出了相应的新技术。
{"title":"Measurement of surface roughness with small waviness by contact stylus instrument correcting specimen orientation","authors":"N. Cho, T. Tsukada, Masaaki Takahashi","doi":"10.2493/JJSPE.59.1871","DOIUrl":"https://doi.org/10.2493/JJSPE.59.1871","url":null,"abstract":"This paper presents the new technique to measure the surface roughness profiles correcting an orientation of specimen surface in one operation. The contact stylus profilometer is equipped with the table whose inclination is controlled by the computer. The positioning of the stylus tip in the vertical direction is corrected at the same time. For assuring to measure profiles in length of 5.6mm, the surface profile data for control is demanded to be obtained in the length of 1mm. This measuring length varies depending on form errors such as the waviness. Then this paper gives the new technique to correspond the above-mentioned problem.","PeriodicalId":14336,"journal":{"name":"International Journal of The Japan Society for Precision Engineering","volume":"148 1","pages":"74-79"},"PeriodicalIF":0.0,"publicationDate":"1993-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77341215","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
The Estimation and Improvement of TTL Alignment Error Budgets for an Excimer Laser Aligner. 准分子激光对准仪TTL对准误差估计及改进。
Pub Date : 1993-01-01 DOI: 10.2493/jjspe.59.1331
T. Higashiki, T. Tojo, M. Tabata, T. Nishizaka, H. Yoshino, S. Saito
This paper describes studies on the alignment error budgets caused by a TTL (through the lens) alignment optical system (SMART : separated mark TTL alignment) for an excimer laser aligner. Alignment error factors, such as the optical phase fluctuation of the alignment beam, the inclination variation of the alignment incident beam, the tilt of the wafer and the reticle, and the defocus of the reticle, have been analyzed and estimated. It was demonstrated that the total error of the alignment optical system was required to be better than 0.02 μm in order to satisfy the positioning strategy of the excimer laser aligner with a 0.05 μm (3σ) overlay accuracy. Several compensation methods have been developed and adopted to SMART. As a result, it was obtained experimentally that the total error of the alignment optical system became better than 0.02 μm. It has met the development goal. The new SMART optical system which was adopted to the KrF excimer laser aligner showed an excellent performance with a better than 0.05 μm (3σ) overlay accuracy.
本文研究了准分子激光准直仪的TTL(通过透镜)准直光学系统(SMART:分离标记TTL准直)的准直误差预算。分析和估计了准直光束的光学相位波动、准直入射光束的倾角变化、晶片和准星的倾斜以及准星的离焦等准直误差因素。结果表明,准分子激光准直仪的覆盖精度为0.05 μm (3σ),为了满足准分子激光准直仪的定位要求,准分子准直光学系统的总误差必须小于0.02 μm。SMART已经开发并采用了几种补偿方法。实验结果表明,准直光学系统的总误差优于0.02 μm。实现了发展目标。应用于KrF准分子激光准直仪的SMART光学系统性能优异,覆盖精度优于0.05 μm (3σ)。
{"title":"The Estimation and Improvement of TTL Alignment Error Budgets for an Excimer Laser Aligner.","authors":"T. Higashiki, T. Tojo, M. Tabata, T. Nishizaka, H. Yoshino, S. Saito","doi":"10.2493/jjspe.59.1331","DOIUrl":"https://doi.org/10.2493/jjspe.59.1331","url":null,"abstract":"This paper describes studies on the alignment error budgets caused by a TTL (through the lens) alignment optical system (SMART : separated mark TTL alignment) for an excimer laser aligner. Alignment error factors, such as the optical phase fluctuation of the alignment beam, the inclination variation of the alignment incident beam, the tilt of the wafer and the reticle, and the defocus of the reticle, have been analyzed and estimated. It was demonstrated that the total error of the alignment optical system was required to be better than 0.02 μm in order to satisfy the positioning strategy of the excimer laser aligner with a 0.05 μm (3σ) overlay accuracy. Several compensation methods have been developed and adopted to SMART. As a result, it was obtained experimentally that the total error of the alignment optical system became better than 0.02 μm. It has met the development goal. The new SMART optical system which was adopted to the KrF excimer laser aligner showed an excellent performance with a better than 0.05 μm (3σ) overlay accuracy.","PeriodicalId":14336,"journal":{"name":"International Journal of The Japan Society for Precision Engineering","volume":"5 1","pages":"1331-1336"},"PeriodicalIF":0.0,"publicationDate":"1993-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73245109","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Study on Vibration-Free Load Sensor -Fundamental Principle- 无振动负载传感器的基本原理研究
Pub Date : 1993-01-01 DOI: 10.2493/JJSPE.59.89
A. Tanifuji
This paper presents the fundamentals for eliminating overshoot and vibration produced by dynamic loading, especially impact force in material tests. Overshoot and vibration are usually eliminated from original values with dampers and filters, since they prevent determination of true loading values. The fundamentals make it possible to determine values for eliminating undesirable phenomena.Three model sensors based on the above fundamentals were made to confirm effectiveness. From experimental results, the validity of the fundamentals as a load sensor for eliminating the overshoot and vibration was confirmed practically.
本文介绍了在材料试验中消除动载荷,特别是冲击载荷产生的超调和振动的基本原理。超调量和振动通常用阻尼器和过滤器从原始值中消除,因为它们妨碍了真实负载值的确定。基本原理使确定消除不良现象的值成为可能。在此基础上制作了三种传感器模型,验证了其有效性。从实验结果来看,实际验证了基板作为负载传感器消除超调和振动的有效性。
{"title":"Study on Vibration-Free Load Sensor -Fundamental Principle-","authors":"A. Tanifuji","doi":"10.2493/JJSPE.59.89","DOIUrl":"https://doi.org/10.2493/JJSPE.59.89","url":null,"abstract":"This paper presents the fundamentals for eliminating overshoot and vibration produced by dynamic loading, especially impact force in material tests. Overshoot and vibration are usually eliminated from original values with dampers and filters, since they prevent determination of true loading values. The fundamentals make it possible to determine values for eliminating undesirable phenomena.Three model sensors based on the above fundamentals were made to confirm effectiveness. From experimental results, the validity of the fundamentals as a load sensor for eliminating the overshoot and vibration was confirmed practically.","PeriodicalId":14336,"journal":{"name":"International Journal of The Japan Society for Precision Engineering","volume":"22 1","pages":"68-73"},"PeriodicalIF":0.0,"publicationDate":"1993-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74217241","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Shape Analysis of Solidified Photopolymer for the Three Dimensional Photofabrication -Measurement of Critical Exposure- 三维光加工用固化光聚合物的形状分析-临界曝光量的测量
Pub Date : 1993-01-01 DOI: 10.2493/JJSPE.59.1477
H. Narahara, Katsumasa Saito
This paper discusses about critical exposure value for the three dimensional photofabrication. Critical exposure is one of the important parameters for photopolymers to explain solidified depth in a conventional model. In this paper, critical exposures of several photopolymers are measured and the results show that the critical exposure is not constant value contrary to the conventional model but the laser power and scan speed have non-linear relationship. The fact that critical exposure is not constant value affected by exposure condition makes it difficult to compare between experiments under conventional model. This paper also discusses the reason of this non-linear experimental results with the consideration of the extent of reaction of photopolymers.
本文讨论了三维光加工的临界曝光值。在传统模型中,临界曝光是光聚合物解释固化深度的重要参数之一。本文对几种光聚合物的临界曝光量进行了测量,结果表明,临界曝光量不是与传统模型相反的恒定值,而是激光功率与扫描速度呈非线性关系。由于临界暴露不是受暴露条件影响的恒定值,使得常规模型下的实验难以进行比较。考虑到光聚合物的反应程度,本文还讨论了实验结果非线性的原因。
{"title":"Shape Analysis of Solidified Photopolymer for the Three Dimensional Photofabrication -Measurement of Critical Exposure-","authors":"H. Narahara, Katsumasa Saito","doi":"10.2493/JJSPE.59.1477","DOIUrl":"https://doi.org/10.2493/JJSPE.59.1477","url":null,"abstract":"This paper discusses about critical exposure value for the three dimensional photofabrication. Critical exposure is one of the important parameters for photopolymers to explain solidified depth in a conventional model. In this paper, critical exposures of several photopolymers are measured and the results show that the critical exposure is not constant value contrary to the conventional model but the laser power and scan speed have non-linear relationship. The fact that critical exposure is not constant value affected by exposure condition makes it difficult to compare between experiments under conventional model. This paper also discusses the reason of this non-linear experimental results with the consideration of the extent of reaction of photopolymers.","PeriodicalId":14336,"journal":{"name":"International Journal of The Japan Society for Precision Engineering","volume":"111 1","pages":"311-316"},"PeriodicalIF":0.0,"publicationDate":"1993-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"79022726","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Electron theory based on quantum mechanics in future precision engineering 基于量子力学的电子理论在未来精密工程中的应用
Pub Date : 1993-01-01 DOI: 10.2493/jjspe.59.869
Y. Mori
{"title":"Electron theory based on quantum mechanics in future precision engineering","authors":"Y. Mori","doi":"10.2493/jjspe.59.869","DOIUrl":"https://doi.org/10.2493/jjspe.59.869","url":null,"abstract":"","PeriodicalId":14336,"journal":{"name":"International Journal of The Japan Society for Precision Engineering","volume":"1 1","pages":"311-314"},"PeriodicalIF":0.0,"publicationDate":"1993-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83014550","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Development of an LED with a Fresnel lens 菲涅耳透镜LED的研制
Pub Date : 1993-01-01 DOI: 10.2493/jjspe.59.655
Yuji Yamazaki, Kazuhito Nakamura, H. Hashimoto
This paper presents the development of an LED with an Fresnel lens to be used in an optical sensor. In a conventional LED a lens and an element are separated, and so must be aligned. Using an LED with a Fresnel lens, both parts are combined so alignment is not necessary. The Fresnel lens was developed because of its thin structure and good optical characteristics. Conventionally, the Fresnel lens has been fabricated by means of electron beam lithography, but it was very time consuming. To solve this problem and fabricate an LED with a Fresnel lens, a diamond turning machine was developed. This machine is used to fabricate molds for Fresnel lenses. By using these molds and inserting LED chips during the injection molding process, an LED with a Fresnel lens can be fabricated. Compared to a conventional LED with a spherical lens, the thickness of the LED is reduced by 70%, and its volume by 50%. Also the LED with a Fresnel lens emits three times as much light as a conventional LED. It is expected that when this LED is used in an optical sensor, its reduced thickness and good optical characteristics will result in a thinner sensor with improved sensitivity.
本文介绍了一种用于光学传感器的带菲涅耳透镜的LED的研制。在传统的LED中,透镜和元件是分开的,因此必须对齐。使用带有菲涅耳透镜的LED,两个部分结合在一起,因此不需要校准。菲涅耳透镜因其薄的结构和良好的光学特性而得到发展。传统的菲涅耳透镜是用电子束光刻的方法制作的,但这种方法非常耗时。为了解决这一问题,研制了一种带菲涅耳透镜的金刚石车床。这台机器是用来制作菲涅耳透镜的模具。通过使用这些模具并在注塑过程中插入LED芯片,可以制造出带有菲涅耳透镜的LED。与带有球形透镜的传统LED相比,LED的厚度减少了70%,体积减少了50%。此外,带有菲涅耳透镜的LED发出的光是传统LED的三倍。预计当该LED用于光学传感器时,其减小的厚度和良好的光学特性将使传感器更薄,灵敏度更高。
{"title":"Development of an LED with a Fresnel lens","authors":"Yuji Yamazaki, Kazuhito Nakamura, H. Hashimoto","doi":"10.2493/jjspe.59.655","DOIUrl":"https://doi.org/10.2493/jjspe.59.655","url":null,"abstract":"This paper presents the development of an LED with an Fresnel lens to be used in an optical sensor. In a conventional LED a lens and an element are separated, and so must be aligned. Using an LED with a Fresnel lens, both parts are combined so alignment is not necessary. The Fresnel lens was developed because of its thin structure and good optical characteristics. Conventionally, the Fresnel lens has been fabricated by means of electron beam lithography, but it was very time consuming. To solve this problem and fabricate an LED with a Fresnel lens, a diamond turning machine was developed. This machine is used to fabricate molds for Fresnel lenses. By using these molds and inserting LED chips during the injection molding process, an LED with a Fresnel lens can be fabricated. Compared to a conventional LED with a spherical lens, the thickness of the LED is reduced by 70%, and its volume by 50%. Also the LED with a Fresnel lens emits three times as much light as a conventional LED. It is expected that when this LED is used in an optical sensor, its reduced thickness and good optical characteristics will result in a thinner sensor with improved sensitivity.","PeriodicalId":14336,"journal":{"name":"International Journal of The Japan Society for Precision Engineering","volume":"50 1","pages":"126-131"},"PeriodicalIF":0.0,"publicationDate":"1993-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82262991","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
FEM analysis on three dimensional cutting: analysis on large deformation problem of tool entry 三维切削的有限元分析:刀具入口大变形问题分析
Pub Date : 1993-01-01 DOI: 10.2493/JJSPE.59.1275
H. Sasahara, T. Obikawa, T. Shirakashi
Tool entry process in three dimensional cutting is simulated by finite element method. Since the chip forming process is one of large deformation problems, geometrical nonlinearity due to the change of shape is introduced into finite element formulation. Constant strain tetrahedra element is used and over-constraint of incompressibility on the deformation of the finite elements in plastic region is relaxed using Nagategaal-Rice functional to make the elements as deformable as real continuum. The chip formation from tool entry to steady state is realized in the analysis and stress and strain distributions in chip and machined surfaces are also obtained. Lower shear angle at side surface of the work, side flow and chip flow direction predicted are in good agreement with experimental results of cutting of plasticine.
采用有限元方法对三维切削中的刀具进刀过程进行了模拟。由于切屑成形过程是大变形问题之一,将形状变化引起的几何非线性引入有限元公式中。采用恒应变四面体单元,利用nagategal - rice泛函放宽了有限元在塑性区不可压缩变形的过度约束,使单元具有实连续体的可变形性。分析中实现了切屑从刀具进入到稳定状态的形成过程,得到了切屑和加工表面的应力应变分布。所预测的工件侧面较低的剪切角、侧流和切屑流向与塑泥切削实验结果吻合较好。
{"title":"FEM analysis on three dimensional cutting: analysis on large deformation problem of tool entry","authors":"H. Sasahara, T. Obikawa, T. Shirakashi","doi":"10.2493/JJSPE.59.1275","DOIUrl":"https://doi.org/10.2493/JJSPE.59.1275","url":null,"abstract":"Tool entry process in three dimensional cutting is simulated by finite element method. Since the chip forming process is one of large deformation problems, geometrical nonlinearity due to the change of shape is introduced into finite element formulation. Constant strain tetrahedra element is used and over-constraint of incompressibility on the deformation of the finite elements in plastic region is relaxed using Nagategaal-Rice functional to make the elements as deformable as real continuum. The chip formation from tool entry to steady state is realized in the analysis and stress and strain distributions in chip and machined surfaces are also obtained. Lower shear angle at side surface of the work, side flow and chip flow direction predicted are in good agreement with experimental results of cutting of plasticine.","PeriodicalId":14336,"journal":{"name":"International Journal of The Japan Society for Precision Engineering","volume":"61 4 1","pages":"1275-1280"},"PeriodicalIF":0.0,"publicationDate":"1993-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86800942","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 16
Focused Ion Beam Assisted Etching of Aluminum. 聚焦离子束辅助蚀刻铝。
Pub Date : 1993-01-01 DOI: 10.2493/JJSPE.59.1531
F. Itoh, Junzo Azuma, S. Haraichi, A. Shimase
Focused ion beam (FIB) milling is widely used for circuit repair, mask repair, and SEM sample prepair for cross-section observation. In the circuit repair application, it is important to achive a higher material selectivity of Al/SiO2, and a higher milling rate. In order to realize both of these, focused ion beam assisted etching (FIBAE), where a chlorine containing gas is injected towards the milling site, was performed. Using Cl2 gas only caused a significant side etch, though the etching rate of aluminum was quite high. When etching Al-Cu-Si alloy with a chlorine containing gas, a residue of Cu-Cl compound was formed. This can be decreased by heating the sample as high as 200°C. An etching selectivity (Al/SiO2) of 100 was achived, without side-etching, by a gas mixture of SiCl4 (95%) and Cl2 (5%).
聚焦离子束(FIB)铣削广泛应用于电路修复、掩模修复和SEM样品制备的截面观察。在电路修复应用中,实现更高的Al/SiO2材料选择性和更高的铣削速率是重要的。为了实现这两个目标,进行了聚焦离子束辅助蚀刻(FIBAE),其中向铣削部位注入含氯气体。使用Cl2气体只引起明显的侧蚀刻,尽管铝的蚀刻率相当高。在含氯气体中蚀刻铝铜硅合金时,会形成残留的Cu-Cl化合物。这可以通过将样品加热到高达200°C来降低。在SiCl4(95%)和Cl2(5%)的混合气体中,在没有侧刻的情况下,Al/SiO2的选择性为100。
{"title":"Focused Ion Beam Assisted Etching of Aluminum.","authors":"F. Itoh, Junzo Azuma, S. Haraichi, A. Shimase","doi":"10.2493/JJSPE.59.1531","DOIUrl":"https://doi.org/10.2493/JJSPE.59.1531","url":null,"abstract":"Focused ion beam (FIB) milling is widely used for circuit repair, mask repair, and SEM sample prepair for cross-section observation. In the circuit repair application, it is important to achive a higher material selectivity of Al/SiO2, and a higher milling rate. In order to realize both of these, focused ion beam assisted etching (FIBAE), where a chlorine containing gas is injected towards the milling site, was performed. Using Cl2 gas only caused a significant side etch, though the etching rate of aluminum was quite high. When etching Al-Cu-Si alloy with a chlorine containing gas, a residue of Cu-Cl compound was formed. This can be decreased by heating the sample as high as 200°C. An etching selectivity (Al/SiO2) of 100 was achived, without side-etching, by a gas mixture of SiCl4 (95%) and Cl2 (5%).","PeriodicalId":14336,"journal":{"name":"International Journal of The Japan Society for Precision Engineering","volume":"22 1","pages":"211-216"},"PeriodicalIF":0.0,"publicationDate":"1993-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86506480","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
International Journal of The Japan Society for Precision Engineering
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1